True Inch Standard for Homes

True Inch Standard for Homes

Part 2-IN: India

TIS-INEdition 1.0Trial useOctober 2026

Used with Part 1: Method, edition 1.0. Published for trial use until October 2028: the score is validated against panels of practising architects in each market, and the text is open for comment (Part 1, Foreword).

How a True Inch Score is madethe method page, every check's curve drawn

Contents
  1. Foreword
  2. Introduction
  3. 1 Scope
  4. 2 Normative references
  5. 3 Terms and definitions
  6. 4 Inputs, switches and defaults
  7. 5 Climate
  8. 6 The checks
    1. 6.1 SpaceSP-1SP-2SP-3SP-4SP-5SP-6SP-7SP-8SP-9SP-10
    2. 6.2 DaylightDL-1DL-2DL-3
    3. 6.3 SunSN-1SN-2
    4. 6.4 AirAR-1AR-2AR-3AR-4AR-5AR-6AR-7
    5. 6.5 LayoutLY-1LY-2LY-3LY-4LY-5LY-6
    6. 6.6 Safety & accessSF-1SF-2SF-3SF-5SF-6
  9. 7 Weights
  10. 8 Critical issues (caps)
  11. 9 The size check
  12. 10 Facts and lenses shown, not scored
  13. Annex A (normative): Corpus anchors
  14. Annex B (normative): Climate and city rules
  15. Annex C (normative): Room hours and the design household
  16. Annex D (normative): Furniture and clearances (Indian sizes)
  17. Annex E (normative): Conformance plans
  18. Annex F (informative): Sources, and what to confirm
  19. Annex G (informative): Where the texts disagree, and what this Part does

Foreword

This is a private standard published by Trueinch. It is not an Indian Standard published by the Bureau of Indian Standards.

What it is. This Part sets the checks, thresholds, climate rules, room hours and area rules for homes in India. The method that turns them into a True Inch Score is in Part 1, and the way the standard is kept is in the Procedures.

Where its values come from. The values come from three kinds of source:

  • Public texts, read in their own words:

    • the National Building Code 2016 and the Model Building Bye-Laws 2016;

    • Eco-Niwas Samhita, the energy code for homes;

    • the Indian Standards IS 2440, IS 3362, IS 7662, IS 3861, IS 4912 and SP 41;

    • the RERA Act and its model agreement;

    • the Harmonised Guidelines 2021;

    • the development control rules of the main cities;

    • IGBC Green Homes.

  • Public summaries of international standards: EN 17037, ASHRAE 55, NKBA.

  • Where nothing sets a level, our own measure, stated as such, with its reason in Annex F.

Editions.

  • NBC. BIS now lists SP 7:2026, the National Building Construction Standards 2026, as superseding NBC 2016. Its text was not yet freely available when this edition was written. Every NBC value here is from the 2016 text, cited as "NBC 2016", and shall be checked against the 2026 text before this edition leaves trial use.

  • Eco-Niwas Samhita is cited in its 2024 consolidation of the 2018 and 2021 parts. Its formula, coefficients, orientation factors and openable ratios are unchanged from 2018.

What binds and what doesn't. NBC is a model code. It binds only where state bye-laws adopt it, and each city's own rules govern there. This Part uses NBC by default and the city's rule where the city is known (Annex B), and says which it used.

Introduction

India's buyers judge flats inside towers, mostly from a brochure, often before the building exists. They care about:

  • facing;

  • the floor;

  • the carpet area against what they are charged;

  • a cross-breeze;

  • cooking smells;

  • light that doesn't bring the afternoon heat with it.

Ceiling fans are everywhere and air conditioning is still a minority, so natural air carries full weight. Window grilles are common, so India has no escape-window rule. This Part is written around those facts.

1Scope

1.1 This Part applies to dwellings in India:

  • flats in apartment buildings (NBC occupancy A-4);

  • independent houses, villas, row houses and builder floors (A-2);

  • duplex and penthouse units;

  • low-income and affordable units, under NBC Annex C, IS 8888 and MBBL §3.4.6.

1.2 It does not apply to hostels, paying-guest accommodation, service apartments or dormitories.

2Normative references

Codes and bye-laws

TextEdition and sections
BIS, National Building Code of India 2016 (SP 7)Part 3 (§2, §12, §13, §20, Annex B, Annex C); Part 4 (residential provisions); Part 6 Sec 8 (glazing and guards, Table 35); Part 8 Sec 1 (lighting and natural ventilation), Sec 3 (IMAC), Sec 4 (acoustics); Part 9 Sec 4 (gas)
MoHUA, Model Building Bye-Laws 2016§3.4.6, §4.3–4.5, §4.12, §4.17, §4.21, §4.29, §4.30, Table 4.5, Chapter 8
BEE, Eco-Niwas Samhita2024 consolidation (2018 Part I; 2021 Part II): RETV, WFRop, VLT, climate zones, the cross-ventilation and daylight provisions, exhaust openings

Indian Standards

StandardUse
IS 2440:1975Daylighting
IS 3362:1977Natural ventilation
IS 7662 (Part 1):1974Orientation
SP 41:1987Functional requirements of buildings
IS 3861:2002Measurement of areas
IS 4912Safety of floor and wall openings, railings: with Amendment 1 (2022)
IS 8888 (Part 1):2020Low-income housing

RERA

  • The Real Estate (Regulation and Development) Act 2016: §2(k), §4(2)(h), §11, §13, §14.

  • The model Agreement for Sale under the central (Union Territory) rules of 2016 (clause 1.7), and the state models.

Accessibility. MoHUA, Harmonised Guidelines and Standards for Universal Accessibility in India 2021.

Green ratings, shown and not scored. IGBC Green Homes v3.0.

References for this Part's levels:

  • EN 17037:2018+A1:2021 and its UK National Annex;

  • ASHRAE 55-2023 (elevated air speed);

  • UK Approved Document F (purge) and M4(2) (bed clearances);

  • NKBA, through public summaries.

City rules (Annex B):

City or stateRules
MaharashtraUDCPR 2020
MumbaiDCPR 2034
DelhiUBBL 2016
HaryanaBuilding Code 2017
GujaratCGDCR 2017
Tamil NaduCDCBR 2019
KeralaKMBR 2019
Karnataka (BBMP) and TelanganaTheir bye-laws, once confirmed

3Terms and definitions

These add to Part 1 §3.

TermDefinition
Habitable roomA room for living, sleeping, eating or study (NBC 2016 Part 3 §2). A kitchen is habitable only where it is also used as a living room; otherwise kitchen rules apply.
BHKThe count of bedrooms, hall (living) and kitchen, as Indian listings use it.
HallThe living room, as Indian plans name it, where it is as large as a habitable room may be (NBC's 7.5 m² and 2.1 m wide); a smaller hall is a passage.
Carpet areaAs RERA §2(k) defines it: the net usable floor area of a flat. It includes internal partition walls. It excludes external walls, areas under service shafts, exclusive balconies or verandahs, and exclusive open terraces.
Utility or dry balconyA covered outdoor space off the kitchen, for washing, a washing machine and drying.
ChajjaA horizontal sunshade over a window.
Shaft or ductA vertical open space that ventilates toilets and kitchens. Its required size grows with the building's height.
Climate zoneOne of the five zones of NBC Part 8: hot-dry, warm-humid, composite, temperate, cold.
Design household1BHK: 2 people · 2BHK: 4 · 3BHK: 5 · 4BHK: 6 · larger: the bedrooms + 2 (Annex C) · a studio or 1RK: 2. Or the owner's household where given.

4Inputs, switches and defaults

4.1 Switches. Each comes from the plan where it can, and otherwise from a question.

SwitchValuesWhat it changes
Building typeFlat; independent house, villa or row house; duplex unitStair rules; balcony and parapet rules; terrain
CityFrom the placeThe city's rules replace NBC's numbers where Annex B lists them
FloorGround; floor numberFall protection, by the floor's height bands; the wind at the floor's height
Low-income unitA plinth of 40 m² or lessThe minimums of NBC Annex C and IS 8888:2020 apply, and the report says "low-income rules applied"

4.2 Defaults. Each default used shall be listed in the report as assumed.

InputDefault
Ceiling height, where not printed3.0 m (SP-8 isn't scored)
Window sill and head900 mm and 2,100 mm
Window typeSliding, two tracks, openable share 0.5
GlazingSingle clear glass: visible transmittance 0.88, SHGC 0.80
Door clear widthA hinged door's opening − 50 mm; a sliding pair's half, − 25 mm; a bifold's opening − 50 mm at each side, where its leaves fold; a pocket door's − 25 mm. A way in with no door hung in it (the open side of a porch) isn't held to a door's sizes
Doors insideOpen by day. Bedroom doors are shut at night (AR-2's still-air test, as Eco-Niwas Samhita assumes)
Kitchen exhaustOff when smells are traced: in a Bengaluru study, hoods ran in only 15% of cooking sessions. A ducted chimney is offered as an improvement
Insect screensNone
TerrainCity for flats; suburban for houses
SurroundingsOpen sky
FloorUnknown (ask)
HouseholdThe design household (§3)

4.3 Questions, in order of value. The report asks only what changes its result:

  1. which way the main door faces, where the plan has no north arrow;

  2. the floor;

  3. the city or project, if the place is vague;

  4. whether the bathroom floor is stepped down;

  5. the sill heights and window type;

  6. the glass (for SN-2);

  7. the wall material (for the Eco-Niwas estimate);

  8. the RERA-registered carpet area and the agreement's area and price (§9).

5Climate

5.1 Zone.

  • Listed cities: Eco-Niwas Samhita's city table (Annex B.1) gives the zone of each city it lists.

  • Other places: the zone comes from the typical year by NBC 2016 Part 8 Table 2, with a zone holding when its season lasts more than six months. Otherwise the place is composite.

  • When the two disagree, the report shows both, and uses the table's zone for code-linked values.

5.2 The typical year. It is PVGIS's typical meteorological year for the place.

5.3 Welcome and unwelcome sun.

w = cool sunny hours ÷ (cool sunny hours + hot sunny hours)

  • Cool is outdoor air at 20 °C or below; hot is 27 °C or above; sunny means direct normal irradiance of at least 120 W/m², in daytime.

  • The 20 °C line sits near the lower edge of IMAC's 80% comfort band at a mild running mean (in winter in Bengaluru, for example).

  • Without the typical year, the zone's default is used: warm-humid 0.05, hot-dry 0.25, composite 0.3, temperate 0.15, cold 0.7.

5.4 Natural ventilation carries full weight in India. The m factor of Part 2-US does not apply.

5.5 Usual wind. This is the condition the airflow checks use.

ElementRule
MonthsThe warm season: months with a mean daily maximum of 30 °C or more. Failing that, Eco-Niwas Samhita's cooling period: February–November in warm-humid zones, March–October elsewhere
Hours18:00–06:00, plus the daytime hours below IMAC's upper 80% limit: the hours windows are opened in
DirectionThe most frequent 45° sector in those hours. The second sector is also run when it carries 25% or more of the hours
SpeedThe median 10 m speed in that sector, brought to the floor's height over its terrain
Still airNo wind: the stack effect alone, the inside 2 K above the outside

Annex B.2 gives the regional patterns that flag a typical year that looks wrong.

5.6 Reference days, where the typical year is missing:

  • The cool season: 21 January.

  • The hot season: the 21st of the two hottest months before the monsoon. That is April and May at or below 20°N, and May and June above it, which keeps the cloudy monsoon months out.

6The checks

How to read the tables.

  • Levels follow Part 1 §6: minimum 50, medium 75, high 100. Zero is where the curve reaches 0 points.

  • "↓" marks a check where less is better.

  • "Kind" names the source's kind: code, model code, city rule, standard, recommendation, convention, or our measure.

6.1Space

SP-1 Room sizes (gate). By NBC 2016 Part 3 §12, or the city's rule (Annex B). There are no grades: fit (SP-2 to SP-4) grades quality. "Width" is the least width of the room's usable rectangle.

RoomThe gate fails when
Habitable roomsThe largest is under 9.5 m² or 2.4 m wide; any other is under 7.5 m² or 2.1 m wide
Kitchen (closed)Under 5.0 m² or 1.8 m wide. 4.5 m² is allowed with a separate store; a kitchen that is also the dining room needs 7.5 m² and 2.1 m
BathUnder 1.8 m² or 1.2 m wide
WCUnder 1.1 m² or 0.9 m wide
Bath and WC combinedUnder 2.8 m² or 1.2 m wide
Store, if drawnUnder 3 m²
LoftCovers more than 25% of its room, or leaves under 2.2 m beneath it
Low-income units (4.1)First room 9.0 m² and 2.5 m wide; second 6.5 m² and 2.1 m; together at least 15.5 m². WC 0.9 m²; bath 1.2 m²; combined 1.8 m²; kitchen 3.3 m² and 1.5 m wide

Notes.

  • NBC words its rules for one and two rooms. "The largest 9.5 m², the rest 7.5 m²" applies them to more rooms, as the city rules write it out.

  • Maharashtra's UDCPR 2020 sets no room minimums: where it applies, only the bath and WC rows are gates.

  • Kind: model code or city rule.

SP-2 Bedroom fit. Each bedroom. The levels are discrete. All bed lengths are 75″.

BedroomMinimumMediumHigh
MainA double (48 × 75″) with a 600 mm walkway along one long side and the footA queen (60 × 75″) with 600 mm on both sides and the footA queen or king (72 × 75″) with 750 mm on both sides and the foot, and room for a desk or dresser (1.0 × 0.5 m)
SecondA single (36 × 75″) with 600 mm alongsideA double, with clearances as for the main bedroom's minimumA queen with 600 mm on both sides
OthersA single with 600 mm alongsideA doubleA double with 600 mm on both sides
Every bedroom, at every levelA wardrobe front with 600 mm clear, and doors that swing clear of the bedAlso a 600 mm route from the door to the window—

Kind: the bed sizes are a convention. The 750 mm clearance is a recommendation (UK Approved Document M4(2) §2.25); the 600 mm clearance is engine practice.

SP-3 Living and dining fit. The living room (the hall) and the dining area. P is the design household.

SpaceMinimumMediumHigh
LivingA three-seat sofa facing a TV at least 2.0 m awayThree plus one seats; a 55″ TV at 1.2–1.6 × its diagonal (SMPTE/THX)Three plus two seats, or an L
DiningA table for P − 1, with a 750 mm chair zoneA table for P, with 900 mm behind chairs that are on a routeA table for P + 2 (guests) with 1,000 mm clear, and the living and dining areas usable at the same time

Kind: recommendation (NKBA's 32/36/44″ seating clearances; SMPTE/THX) and convention.

SP-4 Kitchen capacity. The kitchen. The aisle is in LY-5.

MinimumMediumHigh
A platform run of ≥ 2.4 m (hob, sink, and 600 mm to work on), and a place for a fridge within 3 m of the platformA run of ≥ 3.0 m (L or parallel); the hob on an external wall (for a chimney duct); space for a water purifier by the sinkA run of ≥ 3.6 m, and a tall unit

Kind: convention. The platform is 600 mm deep at 850–900 mm high.

SP-5 Storage. The home: the wardrobe run and the home's storage.

MinimumMediumHigh
A wardrobe of 1.2 m in the main bedroom and 0.9 m in the others1.8 m in the main bedroom, 1.2 m in the others, and a tall kitchen unit or a store2.4 m in the main bedroom, 1.8 m in the others, shoe storage at the entrance, and a loft or a store room

Kind: convention. The UK space standard's built-in storage (1.0–4.0 m²) is the reference.

SP-6 A balcony to sit out. The home's best sit-out. A flat with none drawn is below the minimum, unless its owner says it has one: then it is taken at the minimum until it is drawn.

MinimumMediumHigh
A balcony ≥ 1.2 m deep and ≥ 1.8 m longA sit-out ≥ 1.5 m deep and ≥ 5 m², plus 1 m² for each person beyond twoA sit-out ≥ 1.8 m deep, with another 1 m² for each person

Basis.

  • MBBL allows group-housing balconies 1.2 m wide, at most 3.5 m² per bedroom and three a flat; city rules allow up to 1.5–2.0 m.

  • Kind: our measure. The London Plan's size is the reference [U].

SP-7 Floor that is only for passing ↓. The home: corridors, passages, foyers, landings and stairs that can't be furnished, as a share of the carpet area. A space the drawing leaves unnamed counts where it is as narrow as a passage (1.5 m or less) and opens into two rooms or more.

ZeroMinimumMediumHighScale
30%15%10%7%Linear

Kind: our measure. Its anchors stay provisional: the reference set can't fix them (Annex A).

High 100Medium 75Minimum 5007%10%15%30%% of floor: less is better
Provisional: the reference set can't fix it yet

SP-8 Ceiling height. Gate and grade. Scored only where printed, or given by the owner.

  • Gate fails:

    • a habitable room or kitchen under 2.75 m to the slab soffit;

    • under 2.4 m beneath a beam, or to the false ceiling of an air-conditioned room;

    • a bath or WC under 2.1 m;

    • low-income units under 2.6 m;

    • or the city's rule.

  • The grade: 2.75 m scores 50, and 2.95 m or more scores 100. At that height a ceiling fan hangs at its best height and still clears 2.4 m (NBC Part 8). No Indian standard rewards more.

  • Kind: model code or city rule, and standard.

High 100Medium 75Minimum 5002.4 m2.75 m2.85 m2.95 mm

SP-9 Carry-in. Big pieces reach their rooms through every door and turn. The levels are discrete.

MinimumMediumHigh
A rigid queen mattress (1.52 × 1.9 × 0.2 m) and a double-door fridge (0.70 × 0.75 × 1.75 m)Also a three-seat sofa (2.1 × 0.9 × 0.85 m) and a front-loading washing machineAlso a king mattress, and a module of an L-shaped sofa

Kind: our measure, with Indian sizes.

SP-10 Utility. The home.

MinimumMediumHigh
A place for a washing machine (600 × 600 mm) with water and a drain, in a bath, a utility room or a balconyA utility or dry balcony off the kitchen, with the machine's place and room to dry clothesAlso at least 2 hours of direct sun on its drying lines on a mid-season day

Kind: convention. MBBL allows a 1.2 m drying balcony off the toilet.

6.2Daylight

DL-1 Openings (gate). Each habitable room and the kitchen.

  • The gate fails when the openable area of windows and ventilators is under the zone's share of the floor:

    ZoneShare
    Hot-dry1/10
    Warm-humid1/6
    Temperate and composite1/8
    Cold1/12. Where a state follows MBBL, its §4.30.1.2 sets a floor of 1/10
  • Kitchens need 25% more.

  • What counts: openings to external air or an open verandah: a balcony or a terrace, and the utility, a flat's service balcony, unless it is named a room. They are its windows, its ventilators and its glazed doors, which MBBL §4.30 names among a room's apertures for light and air. A plain door and the frames don't count, the solid parts of a jali are deducted, and only what opens counts: of a partly fixed window, its openable part; of a sliding glass door, the half that opens.

  • City rules replace the ratio (Annex B): for example 1/6, with at least 1 m² for every room, in Mumbai; 1/10 in Maharashtra and Delhi; 1/8 in Haryana.

  • Kind: model code (NBC 2016 Part 3 §20.1.1–20.1.2, §12.3.3(d); MBBL §4.30) or city rule.

  • One gate, two parts. NBC counts only openable area, so this one gate serves both Daylight and Air, and AR-1 is graded only.

DL-2 How bright by day. Each habitable room and the kitchen.

  • The quantity, E50: the illuminance reached over half the work plane (0.75 m) for half the daylight hours. It is the room's median daylight factor × the site's median diffuse horizontal illuminance (the EN 17037 method).

RoomZeroMinimumMediumHighScale
Bedroom10 lux100 lux200 lux300 luxLog
Living, dining15 lux150 lux300 lux500 luxLog
Kitchen20 lux200 lux300 lux500 luxLog
Study, home office20 lux200 lux300 lux500 luxLog

Kinds and sources.

  • Minimum: the UK National Annex to EN 17037 for dwellings (standard).

  • Medium and high: EN 17037's minimum and medium levels (standard).

  • Bedrooms reach 300 at high because Indian bedrooms double as study and work rooms.

Shown with it, not scored:

  • IS 2440's daylight test: a median daylight factor under NBC's clear design sky, on the 0.75 m plane, of 50 lux (living), 150 (study) and 200 (kitchen) at the zone's design sky. It needs the engine to model that sky; until then it is shown "estimated".

  • IGBC Green Homes v3's test: a glazing factor of at least 1 (2 in kitchens), or 110 lux at noon on 21 September under a clear sky.

Edition 1.1 adds a useful-light guard. A room is capped at medium when more than 25% of its work plane exceeds 2,000 lux for more than 10% of daylight hours (the ECBC and GRIHA useful-daylight upper limit). It needs the annual run. Until then, the clear-sky lux at noon on the equinox is shown.

High 100Medium 75Minimum 50010 lux100 lux200 lux300 luxlux, on a logarithmic scale
Bedroom
High 100Medium 75Minimum 50015 lux150 lux300 lux500 luxlux, on a logarithmic scale
Living, dining
High 100Medium 75Minimum 50020 lux200 lux300 lux500 luxlux, on a logarithmic scale
Kitchen
High 100Medium 75Minimum 50020 lux200 lux300 lux500 luxlux, on a logarithmic scale
Study, home office

DL-3 Depth and evenness. Each habitable room.

  • Gate fails when any part of a habitable room is more than 7.5 m from an opening that lights it (NBC 2016 Part 3 §20.1.2 Note 2). UDCPR allows deeper rooms where openings grow in proportion.

  • The quantity, E95: the illuminance reached over 95% of the work plane for half the daylight hours.

ZeroMinimumMediumHighScale
5 lux50 lux100 lux300 luxLog

Kind and source. Standard: EN 17037's minimum and medium second criterion. The minimum is our measure.

Fact shown beside it: depth over window-head height. NBC Part 8 and IS 2440 say a room lit from one side works to 2–2.5 × the head height, and a room 7 m or more across needs openings on opposite sides. With the default 2.1 m head, that is 4.2–5.25 m.

High 100Medium 75Minimum 5005 lux50 lux100 lux300 luxlux, on a logarithmic scale

6.3Sun

The mix. Sun = w · SN-1 + (1 − w) · SN-2, with w from 5.3.

SN-1 Welcome sun. The living room carries 0.6 and the bedroom with the most sun 0.4.

  • The quantity: the hours the room is in sun (Part 1 §5.3) on the cool reference day of 5.6, 21 January. Edition 1.1 averages the typical year's days with cool sunny hours: following the sun through every such day is some ten times a report's work in 1.0.

ZeroMinimumMediumHighScale
0.15 h1.5 h3 h4 hLog

Kind and source. Standard: EN 17037's levels. India has no rule for sun hours; NBC Part 8 §3.4 asks that homes let winter sun in and keep summer sun out, which the mix applies.

High 100Medium 75Minimum 5000.15 h1.5 h3 h4 hhours, on a logarithmic scale

SN-2 Unwelcome sun ↓. Each habitable room.

  • The quantity: solar heat through the glass on hot sunny hours, per m² of floor, in kWh a day. It is computed as clear-sky beam on the glass × SHGC (single clear 0.80 by default), averaged over the hot reference days of 5.6 (edition 1.1: over the typical year's sunny hours at 27 °C or above). Balcony slabs are modelled, and a chajja where the plan has one (the owner's, or an improvement tried), its shadow on the glass and the floor exact; fins are not yet.

ZeroMinimumMediumHighScale
0.380.190.100.05Log

What the levels look like (engine runs in Delhi: a 10.8 m² room with 1.44 m² of glass):

RoomkWh/m² of floor a dayLevel
Bare east or west0.31Short of the minimum
East or west with a 600 mm chajja0.20Just short of the minimum
South-east or south-west with a chajja0.08Between medium and high
North0.08Between medium and high

Chennai's north glass takes summer sun from the north: 0.22, short of the minimum.

Kind and source. Our measure, fixed on the reference set (Annex A, 7 October 2026): its shape, about a factor of two between levels, from Eco-Niwas Samhita's orientation factors and GRIHA's shading test; its minimum where a quarter of the set's rooms fall short, as a quarter fall short of the standards' own.

Shown with it, not scored: the Eco-Niwas check.

  • The plan's part of the RETV: its solar term, c · Σ(A_glass · SHGC · ESF · ω) ÷ A_envelope. A_envelope is the flat's exposed external wall × floor height. Walls onto corridors, shafts and stair or lift cores are left out.

  • The full RETV is shown as a range across three walls (200 mm AAC, 230 mm brick, 150 mm RCC), against Eco-Niwas Samhita's limit of 15 W/m² and its planned 12. The report asks the builder for the wall and the glass.

  • Rough guide: a solar term of 9.0 W/m² or less keeps the RETV near 15 with AAC walls; 6.5 keeps it near 12.

High 100Medium 75Minimum 5000.050.10.190.38kWh a day per m² of floor, on a logarithmic scale: less is better
Fixed on the reference set, 7 October 2026

6.4Air

AR-1 Openable area. Graded only: the gate is DL-1. Each habitable room and the kitchen.

  • The quantity: openable area (what opens of its windows, ventilators and glazed doors, as DL-1 counts it) as a share of the room's floor.

ZoneZeroMinimumMediumHighScale
Warm-humid0%10% (kitchen 8%)16.66%20%Linear
Composite, temperate0%10% (kitchen 8%)12.5%20%Linear
Hot-dry0%10% (kitchen 8%)12%15%Linear
Cold0%8.33%10%12%Linear

Kinds and sources.

  • Minimum: IGBC Green Homes' mandatory level for each room: living 10% and kitchen 8%, falling to 8% and 6% above five floors. In cold zones, Eco-Niwas Samhita's 8.33% applies.

  • Medium: Eco-Niwas Samhita's openable ratio for the zone, applied to each room (it is set for the whole dwelling; code, where notified). In hot-dry zones it is IGBC's credit level, 12%.

  • High:

    • warm-humid and composite: NBC Part 8 §5.4.3.1, where inlets and outlets totalling 20–30% of the floor bring about 30% of the outdoor wind indoors;

    • hot-dry and cold: our measure (provisional), since large openings there let in heat or cold.

  • Shown with it: the dwelling's openable ratio against Eco-Niwas Samhita.

High 100Medium 75Minimum 5000%10%16.66%20%% of the floor
Warm-humid
High 100Medium 75Minimum 5000%10%12.5%20%% of the floor
Composite
High 100Medium 75Minimum 5000%10%12.5%20%% of the floor
Temperate
High 100Medium 75Minimum 5000%10%12%15%% of the floor
Hot-dry
High 100Medium 75Minimum 5000%8.33%10%12%% of the floor
Cold

AR-2 Fresh air. Each habitable room. Its points are the mean of the usual-wind test and the still-air test.

TestZeroMinimumMediumHighScale
Usual wind, windows open by their share0.44610Log
Still air: bedrooms at night, doors shut0.2234Log
Still air: living0.334.56Log

Kinds and sources.

  • Usual wind: the purge rate of UK Approved Document F (4 an hour); IGBC's ventilation-simulation route (6 to qualify, 8–10 for a credit). These are recommendations.

  • Still air: NBC Part 8 §5.2.2.1's bands (bedroom 2–4, living 3–6), as code guidance.

High 100Medium 75Minimum 5000.44610air changes an hour, on a logarithmic scale
Usual wind, windows open by their share
High 100Medium 75Minimum 5000.2234air changes an hour, on a logarithmic scale
Still air: bedrooms at night, doors shut
High 100Medium 75Minimum 5000.334.56air changes an hour, on a logarithmic scale
Still air: living

AR-3 Cross-ventilation. The home.

  • The quantity: the share of regularly occupied floor (living, dining, bedrooms, kitchen, study) in rooms that cross-ventilate.

  • A room cross-ventilates when it has openable outdoor openings on two different façade orientations (opposite or adjacent, never the same wall), or a doorless opening to a room that does. Bedrooms are judged with their doors shut. The engine must also find at least 2 air changes an hour flowing through the room in the usual wind, so a token second opening doesn't count.

ZeroMinimumMediumHighScale
0%50%75%90%Linear

Kind and source. Standard: Eco-Niwas Samhita 2024's graded levels. IGBC's rule for doorless openings is used.

High 100Medium 75Minimum 5000%50%75%90%% of lived-in floor

AR-4 Wet rooms. Each bath, WC and the kitchen.

  • Gate fails when:

    • a bath or WC has no window or ventilator of at least 0.3 m², with no side under 0.3 m, to open air or to a shaft. The shaft's required size grows with the building's height (MBBL Table 4.5: 1.2 m² up to 10 m, up to 9.0 m² above 30 m); above 30 m it needs mechanical ventilation as well;

    • the kitchen has no opening to external air or an open verandah (DL-1's kitchen ratio);

    • a kitchen or bath has no exhaust opening (Eco-Niwas Samhita 2024).

    City rules replace the size (Annex B). Kind: model code, city rule, code.

TestZeroMinimumMediumHighScale
Air changes an hour, usual wind, window open0.66810Log

Basis. IS 3362; NBC Part 8's 6–10. An opening on an external façade rather than a shaft is shown as a fact.

High 100Medium 75Minimum 5000.66810air changes an hour, on a logarithmic scale

AR-5 Smells ↓.

  • The conditions: the usual wind, windows open by their share, doors open by day, the kitchen exhaust off (4.2).

  • The points: half from the first test, a quarter from each of the others.

  • Where the home cooks: its kitchen, or the kitchen of an open plan ("LIVING + DINING + KITCHEN"), where the smell is released; the living room an open kitchen is in is one the smell reaches.

TestZeroMinimumMediumHigh
Kitchen → bedrooms and living: peak share of the kitchen's strength, mean by room hours50%25%10%5%
Time for the living space to clear, after the cooking stops, to a tenth of the kitchen's strongest16 min8 min4 min2 min
WC → kitchen and dining: peak share25%10%5%2%

Kind and source. Our measure, fixed on the reference set (Annex A, 7 October 2026). The set confirmed the first and third tests' provisional anchors. The second's were an hour, from the Bengaluru study's critical window after cooking; with the windows open in the usual wind, half the set's living spaces clear within 4 minutes, and the minimum is where the shares match: about a fifth take longer than 8. A ducted chimney is offered as an improvement, with its effect.

High 100Medium 75Minimum 5005%10%25%50%% of the kitchen's strength: less is better
Kitchen → bedrooms and living: peak share · fixed on the reference set, 7 October 2026
High 100Medium 75Minimum 5002 min4 min8 min16 minminutes: less is better
Time for the living space to clear, after the cooking stops · fixed on the reference set, 7 October 2026
High 100Medium 75Minimum 5002%5%10%25%% of the WC's strength: less is better
WC → kitchen and dining: peak share · fixed on the reference set, 7 October 2026

AR-6 A breeze you feel. The living space and each bedroom.

  • The quantity: the air speed where people are (Part 1 §5.3: over the bed in a bedroom, over the seats in the living space) in the usual wind, windows open, with no fans.

  • Shown beside it: the cooling effect in K.

  • Chajjas push the breeze upward (NBC Part 8 §5.4.3(12)); they are not yet modelled in the airflow (edition 1.1), so a chajja tried as an improvement leaves the breeze as it was.

ZeroMinimumMediumHighScale
0.03 m/s0.2 m/s0.5 m/s0.9 m/sLog

Kinds and sources. NBC Part 8 Table 9's desirable air speeds (0.24–0.53 m/s at 30 °C and 70–80% RH) and ASHRAE 55 (1.8 K at 0.9 m/s) are the standards. Field studies in Hyderabad and Chennai flats support the levels.

High 100Medium 75Minimum 5000.03 m/s0.2 m/s0.5 m/s0.9 m/sm/s, on a logarithmic scale

AR-7 A WC opening into the kitchen (gate).

  • Fails when any room with a WC in it has a door, window or other opening directly into a kitchen or cooking space (NBC 2016 Part 3 §12.4.4; MBBL §4.5; Haryana 7.4(4)).

  • A check, not a failure, when it opens into an open-plan living and dining space that contains the cooking counter.

  • A WC window onto a shaft that the kitchen's window also faces belongs to AR-5.

6.5Layout

LY-1 Privacy at the entrance. Seen from just inside the main door, and from the sofa. The levels are discrete.

MinimumMediumHigh
No WC or bath door, and no bed, in view from the door. A shoe zone (0.35 × 0.9 m) beside the door, off the routeAlso no more than 10% of any bedroom's floor in view, a foyer of at least 1.0 × 1.2 m, and no bath door facing the dining table or the sofaAlso a foyer or a turn that hides the living seating (no more than 25% of it in view)

Kind: our measure, after Indian conventions (the foyer, the shoe rack).

LY-2 Daily routes. The routes are door → kitchen, each bedroom → its nearest bath, kitchen → dining, and door → living. The levels are discrete, with lengths on a mirrored log curve between them.

MinimumMediumHigh
A clear width of at least 750 mm, and no route through another bedroom or a bathAt least 900 mm; door → kitchen doesn't cross the living seating; kitchen → dining ≤ 5 mAt least 1,000 mm; the kitchen next to the dining area (≤ 3 m); every bedroom ≤ 6 m from a bath, and the main bedroom with its own

Kind: the walk ratings (Part 1 §5.3) and our measure.

On a drawing. Each route is walked from where a person stands in its room, on the floor joined to the way in (a room's middle is often under its bed or its table, and a corner its furniture closes off is no way in or out); kitchen → dining ends at the dining table, where one is drawn or placed, and a route to a WC compartment at the bathroom it opens into. A route the drawing's floor doesn't join up (something drawn across a doorway, an opening narrower than a person passes sideways) isn't scored, and the report asks about it.

LY-3 Zoning. A bedroom reached only through another bedroom is a cap (§8). The levels are discrete.

MinimumMediumHigh
A bath reachable from the living and dining areas without entering a bedroom (2BHK and up)Bedrooms grouped in a private zone, away from the entranceAlso a common toilet near the entrance or the living room that guests can reach, and a service route (a utility, or a servant's room with a WC in a 3BHK or larger) apart from the living space

Kind: convention (the Indian common toilet and service room).

LY-4 Doors. Every door. The levels are discrete.

MinimumMediumHigh
No two door leaves collide, and no leaf hits a WC, basin or showerAlso no leaf hits the placed furnitureAlso no open leaf narrows a route below 900 mm

Kind: our measure.

LY-5 How the kitchen works. The kitchen. In an Indian galley kitchen the aisle matters more than the triangle. The levels are discrete.

MinimumMediumHigh
The hob and the sink on one run, with ≥ 600 mm to work on between them; the fridge within 4 m; no route through the work zone; an aisle ≥ 900 mmNKBA's legs of 1.2–2.7 m, totalling ≤ 7.9 m; a window at the sink, or within 1.5 m of the hob; an aisle ≥ 1.0 mAn aisle ≥ 1.2 m; the hob ≥ 450 mm from a window and a door; the sink under or beside a window

Kind: recommendation (NKBA; UK Approved Document M4(2)'s 1,200 mm) and convention.

LY-6 Noise by layout (facts, not scored). From NBC 2016 Part 8 Sec 4 §5.2's layout guidance, never called "quiet" or "noisy":

  • a bedroom sharing a wall with a lift, a stair core, a refuse chute or the next flat's living room;

  • a WC cistern or soil duct on a bedroom wall;

  • a kitchen or WC above a bedroom, where floors stack;

  • a bedroom door opening onto the living room.

6.6Safety & access

India has no rule that reaches private homes for access (the Harmonised Guidelines are advisory, and MBBL §8.1 excludes private residences). So SF-1 and SF-2 are graded references, never gates or "duties".

SF-1 Widths and doors.

MinimumMediumHigh
The city rules' door sizes: the entrance and habitable rooms with a 900 mm leaf, bath and WC 750 mm. Internal passages at least 900 mmUniversal design (NBC Table 8(c); the Harmonised Guidelines 2021 §4.10, §6.1): 900 mm clear at the entrance, every habitable room, the kitchen, and one toilet opening off the living room, that toilet 1,800 × 2,300 or 1,500 × 2,500 mm, with its door opening outward or slidingAlso 1,200 mm passages, a 1,500 mm turning space at room doors and between the kitchen counter and the wall, and a 1,500 × 1,500 mm entrance landing

Kind: city rule (UBBL, UDCPR, Haryana) and standard (NBC Annex B; the Harmonised Guidelines).

On a drawing. A width within the drawing's precision of a value (13 mm, across a door's jambs or a passage's walls) is taken as meeting it, as SF-3's stairs are.

SF-2 Step-free. Most Indian plans don't print floor levels, and sunken toilets (25–50 mm) and raised balcony sills are the norm. Where levels are unknown, the check isn't scored, and the report asks "Is the bathroom floor stepped down?".

MinimumMediumHigh
No step on the way from the flat's entrance to the living room, the kitchen and one bedroom. Thresholds ≤ 12 mm, bevelled above 5 mmAlso one bathroom with a threshold ≤ 12 mm (a level shower)Every room and balcony at ≤ 12 mm (≤ 20 mm, bevelled, at a balcony)

Kind: standard (NBC Annex B; the Harmonised Guidelines).

The owner's answer. A bathroom stepped down scores the minimum; a level one, the medium. The rest of the flat is taken as level, as a flat's floors are but for its baths and balconies; the high level asks for the balconies' sills, which a drawing doesn't show.

SF-3 Stairs. Applies to stairs inside a house or duplex. A block's common stairs are building facts.

  • Gate fails when (NBC 2016 Part 3 §12.18; MBBL §4.17; or the city's rule):

    • the width is under 1.0 m (0.75 m in a two-storey row house);

    • the tread is under 250 mm;

    • the riser is over 190 mm;

    • a flight has more than 12 risers (UDCPR and UBBL allow 15);

    • headroom is under 2.2 m.

MinimumMediumHigh
The code is metTread ≥ 300 mm, riser ≤ 150 mm, and a handrailAlso handrails on both sides at 850–950 mm, landings ≥ 1,200 mm, closed risers, no nosings that project, and no winders or spiral

Kind: model code or city rule (gate); standard (NBC Annex B) for the higher levels.

On a drawing.

  • A stair is its flights and landings together: stair outlines within 300 mm of one another. A few steps (fewer than 8 risers drawn: a porch's, a sunk floor's) aren't a stair, nor is anything narrower than 600 mm (a ladder, or a sliver of a stair's reading).

  • The width and the going are measured. One within the drawing's precision of the code's value (13 mm across the stair, 6.5 mm in its treads' spacing, measured over all of them) is taken as meeting it.

  • The riser is the floor-to-floor height (printed, or the usual ceiling and 300 mm of floor) over the risers drawn. A plan cuts a stair on its way up and draws the rest on the floor above, so a riser steeper than the code allows is asked about (is the whole stair drawn, and what is the floor-to-floor height?), never failed. The flight's count of risers is the drawing's.

  • Headroom, handrails, landings' depth and nosings aren't on a drawing: the high level isn't given on the drawing alone.

SF-5 Falls. It needs the floor; a ground floor isn't scored. With the 900 mm sill assumed, windows from the 11th floor up become "check: a 1.1 m guard is expected", never a failure on the assumption alone.

  • Gate fails when balcony, terrace and verandah guards are under 1.0 m (NBC Part 3 §12.11; MBBL §4.12), or the city's height (Mumbai 1.5 m; Gujarat 1.15 m with gaps of 0.15 m at most). It is assumed met unless a lower height is printed.

MinimumMediumHigh
A window's sill, or the barrier in front of it, at least 800 mm up to the 10th floor, 1,100 mm on floors 11–20, and 1,200 mm from the 21stAlso every window with a sill under 900 mm and a drop over 1.2 m is guarded (IS 4912); balcony guards ≥ 1,100 mm (1,200 mm from the 21st floor); no gap over 100 mmAlso glass with a sill under 750 mm and a drop over 1.5 m is laminated safety glass or has a rail; no guard with climbable rungs

Kind: standard (NBC 2016 Part 6 Sec 8 Table 35; IS 4912 with Amendment 1).

On a drawing. A printed sill under the height its floor asks fails the minimum; an assumed one is asked about, and the check isn't scored until it is answered. The guards' heights aren't read from a drawing in edition 1.0: the gate is taken as met, and a home with a balcony is held at the minimum until its guards are known. The high level is a home with no sill under 900 mm and no balcony.

SF-6 Gas and the kitchen (gate and facts).

  • Gate fails when:

    • the kitchen has no opening to external air or an open verandah (also a cap, §8);

    • the kitchen is in a basement;

    • the hob stands under, or at the foot of, a stair (NBC 2016 Part 3 §12.3.3(d); Part 4 §4.7.9, §6.1.2(b)).

  • Facts:

    • whether the kitchen's exhaust can reach an outside wall directly;

    • where an LPG cylinder can stand in a ventilated spot at floor level (Part 9 Sec 4; IS 6044-1);

    • for piped gas, the meter's vent.

7Weights

7.1 Part weights. The defaults of Part 1 §7.3 apply.

7.2 Check weights within parts. Each check's weight is a share of its part. Where a check doesn't apply, it drops out and the rest share its weight.

PartChecks and weights
SpaceSP-2 25 · SP-3 20 · SP-4 15 · SP-5 10 · SP-6 10 · SP-7 5 · SP-8 5 · SP-9 5 · SP-10 5
DaylightDL-2 70 · DL-3 30
SunSN-1 w · SN-2 (1 − w), from 5.3
AirAR-1 10 · AR-2 25 · AR-3 20 · AR-4 10 · AR-5 15 · AR-6 20
LayoutLY-1 15 · LY-2 30 · LY-3 20 · LY-4 10 · LY-5 25
Safety & accessSF-1 35 · SF-2 20 · SF-3 20 · SF-5 25 (SF-6 is a gate)

8Critical issues (caps)

Part 1 §7.4 applies to each of these:

  1. A bedroom or living room with nothing to light it from outside, where the drawing shows windows elsewhere: no window, glazed door or open side to the outside, or to a balcony, a terrace or an open verandah.

  2. A bedroom the way in reaches only through another bedroom (one the drawing's doors don't join to the way in at all is reached another way: a wing with a door of its own).

  3. A kitchen with no opening of any kind (a window, a door, an open side) to external air or an open verandah, its service balcony among them, which is unsafe for gas and smoke.

9The size check

The size check is shown beside the score and never mixed into it.

9.1 Measured from the drawing.

  • The carpet area, as RERA §2(k) defines it: inside the external walls, with internal walls included, and shafts, exclusive balconies or verandahs and exclusive open terraces left out.

  • The balcony, verandah and terrace areas, separately, as RERA §4(2)(h) asks builders to disclose them.

  • IS 3861's "carpet area", which leaves out kitchens, baths and passages, is named as a different definition and never labelled carpet area.

9.2 Compared.

  • Printed sizes against the drawing: "19 of 20 printed sizes match", each with its receipt.

  • Printed areas against the measured ones: agreeing within 3%, close within 8%, or different.

  • The RERA-registered carpet area. The builder must register each unit type's carpet area, and it is public on the state RERA website (§4(2)(h), §11(1)). Where the owner enters it, the report compares the two.

  • "Builder says": carpet, built-up and super built-up area, entered from the brochure or the agreement. Loading is shown both ways, (super − carpet) ÷ carpet and carpet ÷ super, because the press uses both.

  • The price, where given, is shown per measured carpet sq ft.

9.3 The money at stake. Where the agreement's carpet area exceeds the measured one by more than 3% (areas within 3% agree, 9.2) and a price is given, the report shows the shortfall × the agreement's own rate, with its context:

  • the model agreement for sale (clause 1.7) refunds any reduction within 45 days, with interest, and lets the builder charge for an increase of up to 3%;

  • MahaRERA's model makes the clause non-negotiable;

  • the orders in the research file (MahaRERA 2026, the West Bengal tribunal, Telangana RERA) show it applied.

It is labelled: a plan-verified estimate, not a certified measurement; measure at handover, and compare with the agreement.

9.4 A difference of method is not a shortfall. A gap that comes only from the definition is said to be one: for example, an older agreement made under MOFA that counted balconies (MahaRERA, Deepak Pande v. L&T, 2021).

9.5 The verdict line:

  • "Sizes check out";

  • "A size needs a question";

  • "The printed sizes overstate the drawing".

10Facts and lenses shown, not scored

ItemWhat it shows
The Vastu lens (off by default; per home and per link)The plan's eight directional zones from its north. Which zone holds the entrance, the kitchen, the main bedroom, the pooja space, each toilet and the stairs, and whether the centre is open. Described, never scored; never "compliant". Without a north arrow or the owner's facing, there is no Vastu lens
The Eco-Niwas checkSN-2's estimate and the dwelling's openable ratio
IGBC's and IS 2440's daylight testsDL-2
Fan clearance"At 2.4 m to a false ceiling, there is no legal room for a ceiling fan" (NBC Part 8 Sec 2)
Fixed window grillesA fact, never a score
Noise by layoutLY-6

Annex A (normative): Corpus anchors

The rule. The anchors of SN-2 and AR-5 were fixed on the TIS-IN 1.0 reference set by Part 1 §6.4 on 7 October 2026, and are printed in their checks. SP-7's stay provisional: the set can't fix them (A.4). They are fixed again on a larger set during trial use, and change only with a new edition.

A.1 The reference set. The Indian plans of the Trueinch corpus, rebuilt at the current format: 119 plans, 76 of them real (brochures and listings, read by the product) and 43 generated (homes drawn by the corpus's generator in four drawing styles and rendered clean, at low resolution, photographed or as a phone picture, then read like any upload). A plan is a page of its drawing, as the product reads it: 16 of the 119 are a house's upper floor or a building beside it (a garage, a stable), and count for the rooms the checks judge in them. Each is placed at one of five cities in turn; a plan with a north arrow faces as it says (25), and the rest with the top of the drawing to each way in turn (94).

CityZonePlans (real + generated)
BengaluruTemperate24 (16 + 8)
MumbaiWarm-humid24 (15 + 9)
DelhiComposite24 (15 + 9)
ChennaiWarm-humid24 (15 + 9)
AhmedabadHot-dry23 (15 + 8)

A.2 How it was measured. Every plan through the plan's own facts and the airflow network (SP-7 and AR-5); 42 of them through the sun's days as well (SN-2); and a sample of 12 (9 real, 3 generated), spread through the set so that it meets every city and every facing, through every engine but the 3D breeze, for the standard-anchored checks: the light model and the overcast daylight take most of a home's work. AR-6, which the 3D breeze measures, is left out of the yardstick. AR-5 is measured where a plan has a kitchen and a bedroom or living room (97 of the 119). The facts are kept, so the anchors can be fixed again without the engines (scripts/score/reference.py anchors).

A.3 The yardstick. On the sample, the standard-anchored checks leave 25% of the rooms and plans they judge short of their minimum, 39% short of their medium and 54% short of their high:

CheckJudgedShort of the minimumOf the mediumOf the high
SP-226 rooms0%4%4%
SP-311 rooms18%18%36%
DL-256 rooms20%30%45%
DL-356 rooms14%30%77%
SN-119 rooms0%5%5%
AR-156 rooms62%88%95%
AR-246 rooms6%22%33%
AR-310 plans70%90%100%
AR-423 rooms17%17%17%
LY-59 plans33%78%78%
SF-110 plans80%100%100%

A.4 The anchors.

CurveZeroMinimumMediumHighShort of the minimum: provisional → fixedJudged
SN-2, kWh a day per m² of floor0.380.190.100.059% → 26% (scaled)197 rooms
AR-5, kitchen → bedrooms and living50%25%10%5%24% (kept)97 plans
AR-5, time for the living space to clear16 min8 min4 min2 min1% → 21% (scaled)97 plans
AR-5, WC → kitchen and dining25%10%5%2%32% (kept)97 plans
SP-7, floor only for passing30%15%10%7%6% (provisional)117 plans
  • SN-2 was 0.60, 0.30, 0.15 and 0.08: a quarter of the set's rooms take more of the hot days' sun through their glass than its minimum, as the bare east or west room of 6.3 does, and one with a 600 mm chajja just does.

  • AR-5's clearing was 120, 60, 30 and 15 minutes: with the windows open in the usual wind, the set's living spaces clear in minutes (half within 4, nine in ten within 12), and 27 of the 97 never get a tenth of the kitchen's strongest at all.

  • SP-7 stays provisional. 80 of the 117 plans (68%) have no floor only for passing as their drawings name it: a flat's passage is mostly part of its living floor, which the measure leaves out. Matching the yardstick would put the minimum at 4% of the floor, and make any passage at all the fault rather than how much of the floor it takes. SP-7 needs a measure of circulation the set can fix: the floor the walks between the doors take, which furniture can't.

Annex B (normative): Climate and city rules

B.1 Climate zones of cities. From Eco-Niwas Samhita's city table, as reproduced by IGBC.

ZoneCities
Warm-humidMumbai, Chennai, Kolkata, Pune, Kochi, Visakhapatnam, Guwahati, Goa (Panaji), Thiruvananthapuram, Bhubaneswar, Mangaluru, Belgaum, Jamnagar, Ratnagiri, Tiruchirappalli and others
CompositeDelhi (and NCR, by adjacency), Hyderabad, Jaipur, Lucknow, Chandigarh, Bhopal, Indore, Nagpur, Dehradun, Patna, Allahabad, Amritsar, Ludhiana, Raipur, Ranchi and others
Hot-dryAhmedabad, Surat, Vadodara, Jodhpur, Bikaner, Jaisalmer, Kota, Aurangabad, Sholapur and others
TemperateBengaluru
ColdShimla, Srinagar, Leh, Manali, Kullu, Shillong, Udhagamandalam and others

Notes.

  • Pune is warm-humid, and Jaipur, Hyderabad and Nagpur composite, in this table. Other sources disagree, and the report shows the zone the typical year gives as well.

  • Cities not listed, such as Coimbatore, are worked out from the typical year by NBC Part 8 Table 2.

B.2 Regional wind patterns. These only flag a typical year that looks wrong; they are not inputs.

RegionPattern
West coast (Mumbai, Goa, Kochi)Strong W/SW in the monsoon; W/NW sea breezes in the afternoon the rest of the year
East coast (Chennai, Visakhapatnam, Bhubaneswar, Kolkata)S/SE sea breezes on summer afternoons; W/SW in the monsoon; NE from October to December
Gangetic plain and north-west (Delhi, Lucknow, Jaipur, Chandigarh)Hot W/NW before the monsoon; E/SE in the monsoon; calm winters
Deccan and centre (Bengaluru, Hyderabad, Pune, Nagpur)Steady W/SW in the monsoon; E/NE in winter

B.3 City rules that replace NBC's numbers. These are read in the rules' own texts. Their later amendments are to be checked before 1.0 leaves trial use.

ItemNBC 2016Maharashtra (UDCPR 2020)Mumbai (DCPR 2034)Delhi (UBBL 2016)Haryana (2017)Gujarat (CGDCR 2017)
First habitable room9.5 m², 2.4 mNoneNo area; every room 2.4 m wideFlats ≤ 50 m²: 7.5 m², 2.1 m; larger: 9.5 m², 2.4 mAs NBCOne room of 9.0 m², 2.4 m
Other rooms7.5 m², 2.1 mNone2.4 m wide7.5 m²7.5 m², 2.4 m (group housing)—
Kitchen5.0 m², 1.8 mNone1.8 m wide3.3 m², 1.8 m / 4.5 m², 2.4 m5.5 m², 1.8 m—
Bath / WC / combined1.8 / 1.1 / 2.8 m²1.0 × 1.2 m / 0.9 × 0.9 m / 1.5 m²1.5 / 1.1 / 2.2 m²1.2–1.8 / 1.0–1.2 / 1.8–2.8 m²As NBCWC 0.9 m²
Openings1/10–1/6 by climate; kitchen +25%1/10; kitchen ≥ 1 m²1/6; ≥ 1 m² a room1/10; kitchen ≥ max(1 m², 1/10)1/81/10, and 1/7 including doors
Bath / WC window0.3 m²0.3 m²0.3 m²0.37 m²0.3 m²0.25 m² to a 0.9 × 0.9 m open space
WC not into the kitchenYes—— (no WC above a kitchen)—Yes—
Bath / WC height2.1 m2.1 m2.2 m2.2 m2.45 m2.1 m
Parapet or guard1.0–1.2 m1.0–1.2 m≥ 1.5 m (as printed)1.0–1.5 m; 1.8 m at ≥ 24 mMaximum only≥ 1.15 m, gaps ≤ 0.15 m
Stair in a dwelling1.0 m; 250 / 190 mm; ≤ 12 risers0.75 m; 25 / 19 cm; ≤ 150.9 m; ≤ 120.9–1.0 m; 25 / 19 cm; ≤ 150.9 m; 25 / 19 cm; ≤ 141.0 m; 250 / 200 mm
Doors—0.90 m; bath/WC 0.75 m0.9 m; 0.7 m0.90 m; 0.75 m0.90 m; 0.75 m—

Karnataka, Tamil Nadu (CDCBR 2019), Telangana and Kerala (KMBR 2019) are in the research notes. They are added here when confirmed.

Annex C (normative): Room hours and the design household

Hours a day, from India's Time Use Surveys (MoSPI). Bedrooms are per occupant; the kitchen and study are totals for the household.

RoomAll hours (Air, Space)Daylight hours, 06:00–18:00 (Daylight, Sun)
Bedroom, per occupant9.5 (8.3 sleeping, 1.2 awake)1.0 (2.0 for an elder or a child)
Living (hall)4.03.0
Dining1.50.7
Kitchen (household total)2.52.0
Study (household total)1.51.5
Bath and WC1.0Not scored
Utility or balcony0.50.5
Pooja room or unit0.3 (smoke from lamps and incense)Not scored

Room weight = its hours × the people who use it:

  • a bedroom: its occupants;

  • the living and dining rooms: the design household;

  • the kitchen and study: their totals as given.

What this means for a 2BHK of four.

PartBedroomsLivingDiningKitchenBathsStudyUtility
Air57%24%9%4%6%—1%
Daylight24%48%11%8%—6%2%

The kitchen's needs are carried by its own higher lux levels and by SP-4 and LY-5.

Basis and households.

  • The hours come from the Time Use Survey 2019 and 2024: sleep about 8.3 h; leisure at home about 2.7 h; domestic work about 3.9 h for women.

  • Urban households average 4.8 people (Census 2011), and 16% of urban households hold two or more married couples.

  • In a 3BHK or larger, one bedroom is assumed to be an elder's (2 waking hours).

  • A home of more than four bedrooms is assessed for its bedrooms + 2 people (a 5BHK 7, a 6BHK 8): the rule the households of §3 follow from 2BHK on, each bedroom beyond adding one person.

Annex D (normative): Furniture and clearances (Indian sizes)

PieceSize
Mattress (W × L)Single 36 × 75″ · double 48 × 75″ · queen 60 × 75″ · king 72 × 75″. Lengths of 72 or 78″ where shown
Wardrobe600 mm deep, with 600 mm clear in front
Kitchen platform600 mm deep, at 850–900 mm high. Wall units 300–350 mm deep. Chimney 650–750 mm above the hob
FridgeSingle-door 550 × 650 mm; double-door 650 × 700 × 1,700 mm
Front-loading washing machine600 × 600 × 850 mm
SofaThree-seat 2.1 × 0.9 × 0.85 m
TV55″
Dining tableFour seats 1,200 × 750–900 mm; six seats 1,500–1,800 × 900 mm
Shoe cabinet900–1,200 × 300–350 mm
Pooja unit600–900 × 300–450 mm, or a room of about 1.2 × 1.2 m
Servant's roomAbout 2.4 × 2.4 m, with its own WC

Clearances:

WhereClearance
Bed600 mm (minimum), 750 mm (high)
Dining chairs750 / 900 / 1,000 mm
Kitchen aisle900 / 1,000 / 1,200 mm
In front of a WC or basin600 mm (NBC)

Annex E (normative): Conformance plans

The conformance plans are reference plans with their expected scores and tolerances (Part 1 §11). They are published with the reference set.

Annex F (informative): Sources, and what to confirm

The research notes behind each number:

  • G: Indian codes, measurement, accessibility and safety;

  • H: Indian households, climate, green and comfort standards;

  • K: method;

  • the research.

To confirm before 1.0 leaves trial use:

  • every NBC value against the 2026 text;

  • the city rules' later amendments, and the southern states' values;

  • IMAC-R's equation for homes. Until then, IMAC's 80% band stands in;

  • NBC Part 8 Table 9's partly illegible row;

  • the London Plan's balcony size;

  • Indian mattress sizes, for which there is no BIS standard;

  • MahaRERA's model clause and its order number;

  • SP-7's anchors, on a measure of circulation the reference set can fix (Annex A);

  • w by city, computed on the typical years.

Annex G (informative): Where the texts disagree, and what this Part does

TopicThe disagreementWhat TIS-IN does
OpeningsNBC counts only openable area; the plan once had two code checks for itOne gate (DL-1); AR-1 graded only
Glazed doorsNBC 2016 §20.1.2 counts windows and ventilators, "excluding doors"; MBBL 2016 §4.30 names glazed doors among a room's apertures for light and airA glazed door counts by what opens of it; a plain door doesn't
The utilityA flat's utility is its service balcony, open to the air; a house's utility room is a roomOpen to the air, as a balcony is, unless it is named a room
Carpet areaNBC defers to IS 3861, which leaves out kitchens and baths; RERA §2(k) includes themRERA's carpet area only; IS 3861 named as different
Third and later roomsNBC 12.2.2 words one or two rooms"The largest 9.5 m², the rest 7.5 m²", as the city rules write it
Air changesNBC: bedroom 2–4, no kitchen row; IS 3362: bedroom and living 3, wet rooms 6NBC's bands for the still-air test; IS 3362 for wet rooms
Cross-ventilationIGBC counts any two orientations from 25%; Eco-Niwas Samhita counts adjacent or opposite walls from 50%, with doors shutEco-Niwas Samhita's levels; IGBC's rule for doorless openings; an airflow check besides
GuardsNBC Part 3: 1.0–1.2 m; Part 6 Table 35: 1.1 m, 1.2 m higher up; Mumbai: 1.5 mThe gate at NBC Part 3 or the city's rule; Table 35 at medium
Stair risers per flightNBC 12; UDCPR and UBBL 15; Haryana 14NBC, or the city's rule
Climate zonesEco-Niwas Samhita's city table against NBC's rule applied to weatherThe table for listed cities; both shown when they differ
Daylight skiesIS 2440 and NBC use a clear design sky (90% of hours); EN 17037 an overcast median (50% of hours)Scored by the EN 17037 method; IS 2440's test shown
GlazingNBC wants more opening in warm-humid zones (1/6); Eco-Niwas Samhita's RETV pushes heat-gaining glass downResolved by climate: Sun's mix, and SN-2's per-room heat
ChajjasThey cut solar gain, but slow the breeze indoorsThe sun modelled; the breeze from edition 1.1