Foreword
This is a private standard published by Trueinch. It is not an Indian Standard published by the Bureau of Indian Standards.
What it is. This Part sets the checks, thresholds, climate rules, room hours and area rules for homes in India. The method that turns them into a True Inch Score is in Part 1, and the way the standard is kept is in the Procedures.
Where its values come from. The values come from three kinds of source:
Public texts, read in their own words:
the National Building Code 2016 and the Model Building Bye-Laws 2016;
Eco-Niwas Samhita, the energy code for homes;
the Indian Standards IS 2440, IS 3362, IS 7662, IS 3861, IS 4912 and SP 41;
the RERA Act and its model agreement;
the Harmonised Guidelines 2021;
the development control rules of the main cities;
IGBC Green Homes.
Public summaries of international standards: EN 17037, ASHRAE 55, NKBA.
Where nothing sets a level, our own measure, stated as such, with its reason in Annex F.
Editions.
NBC. BIS now lists SP 7:2026, the National Building Construction Standards 2026, as superseding NBC 2016. Its text was not yet freely available when this edition was written. Every NBC value here is from the 2016 text, cited as "NBC 2016", and shall be checked against the 2026 text before this edition leaves trial use.
Eco-Niwas Samhita is cited in its 2024 consolidation of the 2018 and 2021 parts. Its formula, coefficients, orientation factors and openable ratios are unchanged from 2018.
What binds and what doesn't. NBC is a model code. It binds only where state bye-laws adopt it, and each city's own rules govern there. This Part uses NBC by default and the city's rule where the city is known (Annex B), and says which it used.
Introduction
India's buyers judge flats inside towers, mostly from a brochure, often before the building exists. They care about:
facing;
the floor;
the carpet area against what they are charged;
a cross-breeze;
cooking smells;
light that doesn't bring the afternoon heat with it.
Ceiling fans are everywhere and air conditioning is still a minority, so natural air carries full weight. Window grilles are common, so India has no escape-window rule. This Part is written around those facts.
1Scope
1.1 This Part applies to dwellings in India:
flats in apartment buildings (NBC occupancy A-4);
independent houses, villas, row houses and builder floors (A-2);
duplex and penthouse units;
low-income and affordable units, under NBC Annex C, IS 8888 and MBBL §3.4.6.
1.2 It does not apply to hostels, paying-guest accommodation, service apartments or dormitories.
2Normative references
Codes and bye-laws
| Text | Edition and sections |
|---|---|
| BIS, National Building Code of India 2016 (SP 7) | Part 3 (§2, §12, §13, §20, Annex B, Annex C); Part 4 (residential provisions); Part 6 Sec 8 (glazing and guards, Table 35); Part 8 Sec 1 (lighting and natural ventilation), Sec 3 (IMAC), Sec 4 (acoustics); Part 9 Sec 4 (gas) |
| MoHUA, Model Building Bye-Laws 2016 | §3.4.6, §4.3–4.5, §4.12, §4.17, §4.21, §4.29, §4.30, Table 4.5, Chapter 8 |
| BEE, Eco-Niwas Samhita | 2024 consolidation (2018 Part I; 2021 Part II): RETV, WFRop, VLT, climate zones, the cross-ventilation and daylight provisions, exhaust openings |
Indian Standards
| Standard | Use |
|---|---|
| IS 2440:1975 | Daylighting |
| IS 3362:1977 | Natural ventilation |
| IS 7662 (Part 1):1974 | Orientation |
| SP 41:1987 | Functional requirements of buildings |
| IS 3861:2002 | Measurement of areas |
| IS 4912 | Safety of floor and wall openings, railings: with Amendment 1 (2022) |
| IS 8888 (Part 1):2020 | Low-income housing |
RERA
The Real Estate (Regulation and Development) Act 2016: §2(k), §4(2)(h), §11, §13, §14.
The model Agreement for Sale under the central (Union Territory) rules of 2016 (clause 1.7), and the state models.
Accessibility. MoHUA, Harmonised Guidelines and Standards for Universal Accessibility in India 2021.
Green ratings, shown and not scored. IGBC Green Homes v3.0.
References for this Part's levels:
EN 17037:2018+A1:2021 and its UK National Annex;
ASHRAE 55-2023 (elevated air speed);
UK Approved Document F (purge) and M4(2) (bed clearances);
NKBA, through public summaries.
City rules (Annex B):
| City or state | Rules |
|---|---|
| Maharashtra | UDCPR 2020 |
| Mumbai | DCPR 2034 |
| Delhi | UBBL 2016 |
| Haryana | Building Code 2017 |
| Gujarat | CGDCR 2017 |
| Tamil Nadu | CDCBR 2019 |
| Kerala | KMBR 2019 |
| Karnataka (BBMP) and Telangana | Their bye-laws, once confirmed |
3Terms and definitions
These add to Part 1 §3.
| Term | Definition |
|---|---|
| Habitable room | A room for living, sleeping, eating or study (NBC 2016 Part 3 §2). A kitchen is habitable only where it is also used as a living room; otherwise kitchen rules apply. |
| BHK | The count of bedrooms, hall (living) and kitchen, as Indian listings use it. |
| Hall | The living room, as Indian plans name it, where it is as large as a habitable room may be (NBC's 7.5 m² and 2.1 m wide); a smaller hall is a passage. |
| Carpet area | As RERA §2(k) defines it: the net usable floor area of a flat. It includes internal partition walls. It excludes external walls, areas under service shafts, exclusive balconies or verandahs, and exclusive open terraces. |
| Utility or dry balcony | A covered outdoor space off the kitchen, for washing, a washing machine and drying. |
| Chajja | A horizontal sunshade over a window. |
| Shaft or duct | A vertical open space that ventilates toilets and kitchens. Its required size grows with the building's height. |
| Climate zone | One of the five zones of NBC Part 8: hot-dry, warm-humid, composite, temperate, cold. |
| Design household | 1BHK: 2 people · 2BHK: 4 · 3BHK: 5 · 4BHK: 6 · larger: the bedrooms + 2 (Annex C) · a studio or 1RK: 2. Or the owner's household where given. |
4Inputs, switches and defaults
4.1 Switches. Each comes from the plan where it can, and otherwise from a question.
| Switch | Values | What it changes |
|---|---|---|
| Building type | Flat; independent house, villa or row house; duplex unit | Stair rules; balcony and parapet rules; terrain |
| City | From the place | The city's rules replace NBC's numbers where Annex B lists them |
| Floor | Ground; floor number | Fall protection, by the floor's height bands; the wind at the floor's height |
| Low-income unit | A plinth of 40 m² or less | The minimums of NBC Annex C and IS 8888:2020 apply, and the report says "low-income rules applied" |
4.2 Defaults. Each default used shall be listed in the report as assumed.
| Input | Default |
|---|---|
| Ceiling height, where not printed | 3.0 m (SP-8 isn't scored) |
| Window sill and head | 900 mm and 2,100 mm |
| Window type | Sliding, two tracks, openable share 0.5 |
| Glazing | Single clear glass: visible transmittance 0.88, SHGC 0.80 |
| Door clear width | A hinged door's opening − 50 mm; a sliding pair's half, − 25 mm; a bifold's opening − 50 mm at each side, where its leaves fold; a pocket door's − 25 mm. A way in with no door hung in it (the open side of a porch) isn't held to a door's sizes |
| Doors inside | Open by day. Bedroom doors are shut at night (AR-2's still-air test, as Eco-Niwas Samhita assumes) |
| Kitchen exhaust | Off when smells are traced: in a Bengaluru study, hoods ran in only 15% of cooking sessions. A ducted chimney is offered as an improvement |
| Insect screens | None |
| Terrain | City for flats; suburban for houses |
| Surroundings | Open sky |
| Floor | Unknown (ask) |
| Household | The design household (§3) |
4.3 Questions, in order of value. The report asks only what changes its result:
which way the main door faces, where the plan has no north arrow;
the floor;
the city or project, if the place is vague;
whether the bathroom floor is stepped down;
the sill heights and window type;
the glass (for SN-2);
the wall material (for the Eco-Niwas estimate);
the RERA-registered carpet area and the agreement's area and price (§9).
5Climate
5.1 Zone.
Listed cities: Eco-Niwas Samhita's city table (Annex B.1) gives the zone of each city it lists.
Other places: the zone comes from the typical year by NBC 2016 Part 8 Table 2, with a zone holding when its season lasts more than six months. Otherwise the place is composite.
When the two disagree, the report shows both, and uses the table's zone for code-linked values.
5.2 The typical year. It is PVGIS's typical meteorological year for the place.
5.3 Welcome and unwelcome sun.
w = cool sunny hours ÷ (cool sunny hours + hot sunny hours)
Cool is outdoor air at 20 °C or below; hot is 27 °C or above; sunny means direct normal irradiance of at least 120 W/m², in daytime.
The 20 °C line sits near the lower edge of IMAC's 80% comfort band at a mild running mean (in winter in Bengaluru, for example).
Without the typical year, the zone's default is used: warm-humid 0.05, hot-dry 0.25, composite 0.3, temperate 0.15, cold 0.7.
5.4 Natural ventilation carries full weight in India. The m factor of Part 2-US does not apply.
5.5 Usual wind. This is the condition the airflow checks use.
| Element | Rule |
|---|---|
| Months | The warm season: months with a mean daily maximum of 30 °C or more. Failing that, Eco-Niwas Samhita's cooling period: February–November in warm-humid zones, March–October elsewhere |
| Hours | 18:00–06:00, plus the daytime hours below IMAC's upper 80% limit: the hours windows are opened in |
| Direction | The most frequent 45° sector in those hours. The second sector is also run when it carries 25% or more of the hours |
| Speed | The median 10 m speed in that sector, brought to the floor's height over its terrain |
| Still air | No wind: the stack effect alone, the inside 2 K above the outside |
Annex B.2 gives the regional patterns that flag a typical year that looks wrong.
5.6 Reference days, where the typical year is missing:
The cool season: 21 January.
The hot season: the 21st of the two hottest months before the monsoon. That is April and May at or below 20°N, and May and June above it, which keeps the cloudy monsoon months out.
6The checks
How to read the tables.
Levels follow Part 1 §6: minimum 50, medium 75, high 100. Zero is where the curve reaches 0 points.
"↓" marks a check where less is better.
"Kind" names the source's kind: code, model code, city rule, standard, recommendation, convention, or our measure.
6.1Space
SP-1 Room sizes (gate). By NBC 2016 Part 3 §12, or the city's rule (Annex B). There are no grades: fit (SP-2 to SP-4) grades quality. "Width" is the least width of the room's usable rectangle.
| Room | The gate fails when |
|---|---|
| Habitable rooms | The largest is under 9.5 m² or 2.4 m wide; any other is under 7.5 m² or 2.1 m wide |
| Kitchen (closed) | Under 5.0 m² or 1.8 m wide. 4.5 m² is allowed with a separate store; a kitchen that is also the dining room needs 7.5 m² and 2.1 m |
| Bath | Under 1.8 m² or 1.2 m wide |
| WC | Under 1.1 m² or 0.9 m wide |
| Bath and WC combined | Under 2.8 m² or 1.2 m wide |
| Store, if drawn | Under 3 m² |
| Loft | Covers more than 25% of its room, or leaves under 2.2 m beneath it |
| Low-income units (4.1) | First room 9.0 m² and 2.5 m wide; second 6.5 m² and 2.1 m; together at least 15.5 m². WC 0.9 m²; bath 1.2 m²; combined 1.8 m²; kitchen 3.3 m² and 1.5 m wide |
Notes.
NBC words its rules for one and two rooms. "The largest 9.5 m², the rest 7.5 m²" applies them to more rooms, as the city rules write it out.
Maharashtra's UDCPR 2020 sets no room minimums: where it applies, only the bath and WC rows are gates.
Kind: model code or city rule.
SP-2 Bedroom fit. Each bedroom. The levels are discrete. All bed lengths are 75″.
| Bedroom | Minimum | Medium | High |
|---|---|---|---|
| Main | A double (48 × 75″) with a 600 mm walkway along one long side and the foot | A queen (60 × 75″) with 600 mm on both sides and the foot | A queen or king (72 × 75″) with 750 mm on both sides and the foot, and room for a desk or dresser (1.0 × 0.5 m) |
| Second | A single (36 × 75″) with 600 mm alongside | A double, with clearances as for the main bedroom's minimum | A queen with 600 mm on both sides |
| Others | A single with 600 mm alongside | A double | A double with 600 mm on both sides |
| Every bedroom, at every level | A wardrobe front with 600 mm clear, and doors that swing clear of the bed | Also a 600 mm route from the door to the window | — |
Kind: the bed sizes are a convention. The 750 mm clearance is a recommendation (UK Approved Document M4(2) §2.25); the 600 mm clearance is engine practice.
SP-3 Living and dining fit. The living room (the hall) and the dining area. P is the design household.
| Space | Minimum | Medium | High |
|---|---|---|---|
| Living | A three-seat sofa facing a TV at least 2.0 m away | Three plus one seats; a 55″ TV at 1.2–1.6 × its diagonal (SMPTE/THX) | Three plus two seats, or an L |
| Dining | A table for P − 1, with a 750 mm chair zone | A table for P, with 900 mm behind chairs that are on a route | A table for P + 2 (guests) with 1,000 mm clear, and the living and dining areas usable at the same time |
Kind: recommendation (NKBA's 32/36/44″ seating clearances; SMPTE/THX) and convention.
SP-4 Kitchen capacity. The kitchen. The aisle is in LY-5.
| Minimum | Medium | High |
|---|---|---|
| A platform run of ≥ 2.4 m (hob, sink, and 600 mm to work on), and a place for a fridge within 3 m of the platform | A run of ≥ 3.0 m (L or parallel); the hob on an external wall (for a chimney duct); space for a water purifier by the sink | A run of ≥ 3.6 m, and a tall unit |
Kind: convention. The platform is 600 mm deep at 850–900 mm high.
SP-5 Storage. The home: the wardrobe run and the home's storage.
| Minimum | Medium | High |
|---|---|---|
| A wardrobe of 1.2 m in the main bedroom and 0.9 m in the others | 1.8 m in the main bedroom, 1.2 m in the others, and a tall kitchen unit or a store | 2.4 m in the main bedroom, 1.8 m in the others, shoe storage at the entrance, and a loft or a store room |
Kind: convention. The UK space standard's built-in storage (1.0–4.0 m²) is the reference.
SP-6 A balcony to sit out. The home's best sit-out. A flat with none drawn is below the minimum, unless its owner says it has one: then it is taken at the minimum until it is drawn.
| Minimum | Medium | High |
|---|---|---|
| A balcony ≥ 1.2 m deep and ≥ 1.8 m long | A sit-out ≥ 1.5 m deep and ≥ 5 m², plus 1 m² for each person beyond two | A sit-out ≥ 1.8 m deep, with another 1 m² for each person |
Basis.
MBBL allows group-housing balconies 1.2 m wide, at most 3.5 m² per bedroom and three a flat; city rules allow up to 1.5–2.0 m.
Kind: our measure. The London Plan's size is the reference [U].
SP-7 Floor that is only for passing ↓. The home: corridors, passages, foyers, landings and stairs that can't be furnished, as a share of the carpet area. A space the drawing leaves unnamed counts where it is as narrow as a passage (1.5 m or less) and opens into two rooms or more.
| Zero | Minimum | Medium | High | Scale |
|---|---|---|---|---|
| 30% | 15% | 10% | 7% | Linear |
Kind: our measure. Its anchors stay provisional: the reference set can't fix them (Annex A).
SP-8 Ceiling height. Gate and grade. Scored only where printed, or given by the owner.
Gate fails:
a habitable room or kitchen under 2.75 m to the slab soffit;
under 2.4 m beneath a beam, or to the false ceiling of an air-conditioned room;
a bath or WC under 2.1 m;
low-income units under 2.6 m;
or the city's rule.
The grade: 2.75 m scores 50, and 2.95 m or more scores 100. At that height a ceiling fan hangs at its best height and still clears 2.4 m (NBC Part 8). No Indian standard rewards more.
Kind: model code or city rule, and standard.
SP-9 Carry-in. Big pieces reach their rooms through every door and turn. The levels are discrete.
| Minimum | Medium | High |
|---|---|---|
| A rigid queen mattress (1.52 × 1.9 × 0.2 m) and a double-door fridge (0.70 × 0.75 × 1.75 m) | Also a three-seat sofa (2.1 × 0.9 × 0.85 m) and a front-loading washing machine | Also a king mattress, and a module of an L-shaped sofa |
Kind: our measure, with Indian sizes.
SP-10 Utility. The home.
| Minimum | Medium | High |
|---|---|---|
| A place for a washing machine (600 × 600 mm) with water and a drain, in a bath, a utility room or a balcony | A utility or dry balcony off the kitchen, with the machine's place and room to dry clothes | Also at least 2 hours of direct sun on its drying lines on a mid-season day |
Kind: convention. MBBL allows a 1.2 m drying balcony off the toilet.
6.2Daylight
DL-1 Openings (gate). Each habitable room and the kitchen.
The gate fails when the openable area of windows and ventilators is under the zone's share of the floor:
Zone Share Hot-dry 1/10 Warm-humid 1/6 Temperate and composite 1/8 Cold 1/12. Where a state follows MBBL, its §4.30.1.2 sets a floor of 1/10 Kitchens need 25% more.
What counts: openings to external air or an open verandah: a balcony or a terrace, and the utility, a flat's service balcony, unless it is named a room. They are its windows, its ventilators and its glazed doors, which MBBL §4.30 names among a room's apertures for light and air. A plain door and the frames don't count, the solid parts of a jali are deducted, and only what opens counts: of a partly fixed window, its openable part; of a sliding glass door, the half that opens.
City rules replace the ratio (Annex B): for example 1/6, with at least 1 m² for every room, in Mumbai; 1/10 in Maharashtra and Delhi; 1/8 in Haryana.
Kind: model code (NBC 2016 Part 3 §20.1.1–20.1.2, §12.3.3(d); MBBL §4.30) or city rule.
One gate, two parts. NBC counts only openable area, so this one gate serves both Daylight and Air, and AR-1 is graded only.
DL-2 How bright by day. Each habitable room and the kitchen.
The quantity, E50: the illuminance reached over half the work plane (0.75 m) for half the daylight hours. It is the room's median daylight factor × the site's median diffuse horizontal illuminance (the EN 17037 method).
| Room | Zero | Minimum | Medium | High | Scale |
|---|---|---|---|---|---|
| Bedroom | 10 lux | 100 lux | 200 lux | 300 lux | Log |
| Living, dining | 15 lux | 150 lux | 300 lux | 500 lux | Log |
| Kitchen | 20 lux | 200 lux | 300 lux | 500 lux | Log |
| Study, home office | 20 lux | 200 lux | 300 lux | 500 lux | Log |
Kinds and sources.
Minimum: the UK National Annex to EN 17037 for dwellings (standard).
Medium and high: EN 17037's minimum and medium levels (standard).
Bedrooms reach 300 at high because Indian bedrooms double as study and work rooms.
Shown with it, not scored:
IS 2440's daylight test: a median daylight factor under NBC's clear design sky, on the 0.75 m plane, of 50 lux (living), 150 (study) and 200 (kitchen) at the zone's design sky. It needs the engine to model that sky; until then it is shown "estimated".
IGBC Green Homes v3's test: a glazing factor of at least 1 (2 in kitchens), or 110 lux at noon on 21 September under a clear sky.
Edition 1.1 adds a useful-light guard. A room is capped at medium when more than 25% of its work plane exceeds 2,000 lux for more than 10% of daylight hours (the ECBC and GRIHA useful-daylight upper limit). It needs the annual run. Until then, the clear-sky lux at noon on the equinox is shown.
DL-3 Depth and evenness. Each habitable room.
Gate fails when any part of a habitable room is more than 7.5 m from an opening that lights it (NBC 2016 Part 3 §20.1.2 Note 2). UDCPR allows deeper rooms where openings grow in proportion.
The quantity, E95: the illuminance reached over 95% of the work plane for half the daylight hours.
| Zero | Minimum | Medium | High | Scale |
|---|---|---|---|---|
| 5 lux | 50 lux | 100 lux | 300 lux | Log |
Kind and source. Standard: EN 17037's minimum and medium second criterion. The minimum is our measure.
Fact shown beside it: depth over window-head height. NBC Part 8 and IS 2440 say a room lit from one side works to 2–2.5 × the head height, and a room 7 m or more across needs openings on opposite sides. With the default 2.1 m head, that is 4.2–5.25 m.
6.3Sun
The mix. Sun = w · SN-1 + (1 − w) · SN-2, with w from 5.3.
SN-1 Welcome sun. The living room carries 0.6 and the bedroom with the most sun 0.4.
The quantity: the hours the room is in sun (Part 1 §5.3) on the cool reference day of 5.6, 21 January. Edition 1.1 averages the typical year's days with cool sunny hours: following the sun through every such day is some ten times a report's work in 1.0.
| Zero | Minimum | Medium | High | Scale |
|---|---|---|---|---|
| 0.15 h | 1.5 h | 3 h | 4 h | Log |
Kind and source. Standard: EN 17037's levels. India has no rule for sun hours; NBC Part 8 §3.4 asks that homes let winter sun in and keep summer sun out, which the mix applies.
SN-2 Unwelcome sun ↓. Each habitable room.
The quantity: solar heat through the glass on hot sunny hours, per m² of floor, in kWh a day. It is computed as clear-sky beam on the glass × SHGC (single clear 0.80 by default), averaged over the hot reference days of 5.6 (edition 1.1: over the typical year's sunny hours at 27 °C or above). Balcony slabs are modelled, and a chajja where the plan has one (the owner's, or an improvement tried), its shadow on the glass and the floor exact; fins are not yet.
| Zero | Minimum | Medium | High | Scale |
|---|---|---|---|---|
| 0.38 | 0.19 | 0.10 | 0.05 | Log |
What the levels look like (engine runs in Delhi: a 10.8 m² room with 1.44 m² of glass):
| Room | kWh/m² of floor a day | Level |
|---|---|---|
| Bare east or west | 0.31 | Short of the minimum |
| East or west with a 600 mm chajja | 0.20 | Just short of the minimum |
| South-east or south-west with a chajja | 0.08 | Between medium and high |
| North | 0.08 | Between medium and high |
Chennai's north glass takes summer sun from the north: 0.22, short of the minimum.
Kind and source. Our measure, fixed on the reference set (Annex A, 7 October 2026): its shape, about a factor of two between levels, from Eco-Niwas Samhita's orientation factors and GRIHA's shading test; its minimum where a quarter of the set's rooms fall short, as a quarter fall short of the standards' own.
Shown with it, not scored: the Eco-Niwas check.
The plan's part of the RETV: its solar term, c · Σ(A_glass · SHGC · ESF · ω) ÷ A_envelope. A_envelope is the flat's exposed external wall × floor height. Walls onto corridors, shafts and stair or lift cores are left out.
The full RETV is shown as a range across three walls (200 mm AAC, 230 mm brick, 150 mm RCC), against Eco-Niwas Samhita's limit of 15 W/m² and its planned 12. The report asks the builder for the wall and the glass.
Rough guide: a solar term of 9.0 W/m² or less keeps the RETV near 15 with AAC walls; 6.5 keeps it near 12.
6.4Air
AR-1 Openable area. Graded only: the gate is DL-1. Each habitable room and the kitchen.
The quantity: openable area (what opens of its windows, ventilators and glazed doors, as DL-1 counts it) as a share of the room's floor.
| Zone | Zero | Minimum | Medium | High | Scale |
|---|---|---|---|---|---|
| Warm-humid | 0% | 10% (kitchen 8%) | 16.66% | 20% | Linear |
| Composite, temperate | 0% | 10% (kitchen 8%) | 12.5% | 20% | Linear |
| Hot-dry | 0% | 10% (kitchen 8%) | 12% | 15% | Linear |
| Cold | 0% | 8.33% | 10% | 12% | Linear |
Kinds and sources.
Minimum: IGBC Green Homes' mandatory level for each room: living 10% and kitchen 8%, falling to 8% and 6% above five floors. In cold zones, Eco-Niwas Samhita's 8.33% applies.
Medium: Eco-Niwas Samhita's openable ratio for the zone, applied to each room (it is set for the whole dwelling; code, where notified). In hot-dry zones it is IGBC's credit level, 12%.
High:
warm-humid and composite: NBC Part 8 §5.4.3.1, where inlets and outlets totalling 20–30% of the floor bring about 30% of the outdoor wind indoors;
hot-dry and cold: our measure (provisional), since large openings there let in heat or cold.
Shown with it: the dwelling's openable ratio against Eco-Niwas Samhita.
AR-2 Fresh air. Each habitable room. Its points are the mean of the usual-wind test and the still-air test.
| Test | Zero | Minimum | Medium | High | Scale |
|---|---|---|---|---|---|
| Usual wind, windows open by their share | 0.4 | 4 | 6 | 10 | Log |
| Still air: bedrooms at night, doors shut | 0.2 | 2 | 3 | 4 | Log |
| Still air: living | 0.3 | 3 | 4.5 | 6 | Log |
Kinds and sources.
Usual wind: the purge rate of UK Approved Document F (4 an hour); IGBC's ventilation-simulation route (6 to qualify, 8–10 for a credit). These are recommendations.
Still air: NBC Part 8 §5.2.2.1's bands (bedroom 2–4, living 3–6), as code guidance.
AR-3 Cross-ventilation. The home.
The quantity: the share of regularly occupied floor (living, dining, bedrooms, kitchen, study) in rooms that cross-ventilate.
A room cross-ventilates when it has openable outdoor openings on two different façade orientations (opposite or adjacent, never the same wall), or a doorless opening to a room that does. Bedrooms are judged with their doors shut. The engine must also find at least 2 air changes an hour flowing through the room in the usual wind, so a token second opening doesn't count.
| Zero | Minimum | Medium | High | Scale |
|---|---|---|---|---|
| 0% | 50% | 75% | 90% | Linear |
Kind and source. Standard: Eco-Niwas Samhita 2024's graded levels. IGBC's rule for doorless openings is used.
AR-4 Wet rooms. Each bath, WC and the kitchen.
Gate fails when:
a bath or WC has no window or ventilator of at least 0.3 m², with no side under 0.3 m, to open air or to a shaft. The shaft's required size grows with the building's height (MBBL Table 4.5: 1.2 m² up to 10 m, up to 9.0 m² above 30 m); above 30 m it needs mechanical ventilation as well;
the kitchen has no opening to external air or an open verandah (DL-1's kitchen ratio);
a kitchen or bath has no exhaust opening (Eco-Niwas Samhita 2024).
City rules replace the size (Annex B). Kind: model code, city rule, code.
| Test | Zero | Minimum | Medium | High | Scale |
|---|---|---|---|---|---|
| Air changes an hour, usual wind, window open | 0.6 | 6 | 8 | 10 | Log |
Basis. IS 3362; NBC Part 8's 6–10. An opening on an external façade rather than a shaft is shown as a fact.
AR-5 Smells ↓.
The conditions: the usual wind, windows open by their share, doors open by day, the kitchen exhaust off (4.2).
The points: half from the first test, a quarter from each of the others.
Where the home cooks: its kitchen, or the kitchen of an open plan ("LIVING + DINING + KITCHEN"), where the smell is released; the living room an open kitchen is in is one the smell reaches.
| Test | Zero | Minimum | Medium | High |
|---|---|---|---|---|
| Kitchen → bedrooms and living: peak share of the kitchen's strength, mean by room hours | 50% | 25% | 10% | 5% |
| Time for the living space to clear, after the cooking stops, to a tenth of the kitchen's strongest | 16 min | 8 min | 4 min | 2 min |
| WC → kitchen and dining: peak share | 25% | 10% | 5% | 2% |
Kind and source. Our measure, fixed on the reference set (Annex A, 7 October 2026). The set confirmed the first and third tests' provisional anchors. The second's were an hour, from the Bengaluru study's critical window after cooking; with the windows open in the usual wind, half the set's living spaces clear within 4 minutes, and the minimum is where the shares match: about a fifth take longer than 8. A ducted chimney is offered as an improvement, with its effect.
AR-6 A breeze you feel. The living space and each bedroom.
The quantity: the air speed where people are (Part 1 §5.3: over the bed in a bedroom, over the seats in the living space) in the usual wind, windows open, with no fans.
Shown beside it: the cooling effect in K.
Chajjas push the breeze upward (NBC Part 8 §5.4.3(12)); they are not yet modelled in the airflow (edition 1.1), so a chajja tried as an improvement leaves the breeze as it was.
| Zero | Minimum | Medium | High | Scale |
|---|---|---|---|---|
| 0.03 m/s | 0.2 m/s | 0.5 m/s | 0.9 m/s | Log |
Kinds and sources. NBC Part 8 Table 9's desirable air speeds (0.24–0.53 m/s at 30 °C and 70–80% RH) and ASHRAE 55 (1.8 K at 0.9 m/s) are the standards. Field studies in Hyderabad and Chennai flats support the levels.
AR-7 A WC opening into the kitchen (gate).
Fails when any room with a WC in it has a door, window or other opening directly into a kitchen or cooking space (NBC 2016 Part 3 §12.4.4; MBBL §4.5; Haryana 7.4(4)).
A check, not a failure, when it opens into an open-plan living and dining space that contains the cooking counter.
A WC window onto a shaft that the kitchen's window also faces belongs to AR-5.
6.5Layout
LY-1 Privacy at the entrance. Seen from just inside the main door, and from the sofa. The levels are discrete.
| Minimum | Medium | High |
|---|---|---|
| No WC or bath door, and no bed, in view from the door. A shoe zone (0.35 × 0.9 m) beside the door, off the route | Also no more than 10% of any bedroom's floor in view, a foyer of at least 1.0 × 1.2 m, and no bath door facing the dining table or the sofa | Also a foyer or a turn that hides the living seating (no more than 25% of it in view) |
Kind: our measure, after Indian conventions (the foyer, the shoe rack).
LY-2 Daily routes. The routes are door → kitchen, each bedroom → its nearest bath, kitchen → dining, and door → living. The levels are discrete, with lengths on a mirrored log curve between them.
| Minimum | Medium | High |
|---|---|---|
| A clear width of at least 750 mm, and no route through another bedroom or a bath | At least 900 mm; door → kitchen doesn't cross the living seating; kitchen → dining ≤ 5 m | At least 1,000 mm; the kitchen next to the dining area (≤ 3 m); every bedroom ≤ 6 m from a bath, and the main bedroom with its own |
Kind: the walk ratings (Part 1 §5.3) and our measure.
On a drawing. Each route is walked from where a person stands in its room, on the floor joined to the way in (a room's middle is often under its bed or its table, and a corner its furniture closes off is no way in or out); kitchen → dining ends at the dining table, where one is drawn or placed, and a route to a WC compartment at the bathroom it opens into. A route the drawing's floor doesn't join up (something drawn across a doorway, an opening narrower than a person passes sideways) isn't scored, and the report asks about it.
LY-3 Zoning. A bedroom reached only through another bedroom is a cap (§8). The levels are discrete.
| Minimum | Medium | High |
|---|---|---|
| A bath reachable from the living and dining areas without entering a bedroom (2BHK and up) | Bedrooms grouped in a private zone, away from the entrance | Also a common toilet near the entrance or the living room that guests can reach, and a service route (a utility, or a servant's room with a WC in a 3BHK or larger) apart from the living space |
Kind: convention (the Indian common toilet and service room).
LY-4 Doors. Every door. The levels are discrete.
| Minimum | Medium | High |
|---|---|---|
| No two door leaves collide, and no leaf hits a WC, basin or shower | Also no leaf hits the placed furniture | Also no open leaf narrows a route below 900 mm |
Kind: our measure.
LY-5 How the kitchen works. The kitchen. In an Indian galley kitchen the aisle matters more than the triangle. The levels are discrete.
| Minimum | Medium | High |
|---|---|---|
| The hob and the sink on one run, with ≥ 600 mm to work on between them; the fridge within 4 m; no route through the work zone; an aisle ≥ 900 mm | NKBA's legs of 1.2–2.7 m, totalling ≤ 7.9 m; a window at the sink, or within 1.5 m of the hob; an aisle ≥ 1.0 m | An aisle ≥ 1.2 m; the hob ≥ 450 mm from a window and a door; the sink under or beside a window |
Kind: recommendation (NKBA; UK Approved Document M4(2)'s 1,200 mm) and convention.
LY-6 Noise by layout (facts, not scored). From NBC 2016 Part 8 Sec 4 §5.2's layout guidance, never called "quiet" or "noisy":
a bedroom sharing a wall with a lift, a stair core, a refuse chute or the next flat's living room;
a WC cistern or soil duct on a bedroom wall;
a kitchen or WC above a bedroom, where floors stack;
a bedroom door opening onto the living room.
6.6Safety & access
India has no rule that reaches private homes for access (the Harmonised Guidelines are advisory, and MBBL §8.1 excludes private residences). So SF-1 and SF-2 are graded references, never gates or "duties".
SF-1 Widths and doors.
| Minimum | Medium | High |
|---|---|---|
| The city rules' door sizes: the entrance and habitable rooms with a 900 mm leaf, bath and WC 750 mm. Internal passages at least 900 mm | Universal design (NBC Table 8(c); the Harmonised Guidelines 2021 §4.10, §6.1): 900 mm clear at the entrance, every habitable room, the kitchen, and one toilet opening off the living room, that toilet 1,800 × 2,300 or 1,500 × 2,500 mm, with its door opening outward or sliding | Also 1,200 mm passages, a 1,500 mm turning space at room doors and between the kitchen counter and the wall, and a 1,500 × 1,500 mm entrance landing |
Kind: city rule (UBBL, UDCPR, Haryana) and standard (NBC Annex B; the Harmonised Guidelines).
On a drawing. A width within the drawing's precision of a value (13 mm, across a door's jambs or a passage's walls) is taken as meeting it, as SF-3's stairs are.
SF-2 Step-free. Most Indian plans don't print floor levels, and sunken toilets (25–50 mm) and raised balcony sills are the norm. Where levels are unknown, the check isn't scored, and the report asks "Is the bathroom floor stepped down?".
| Minimum | Medium | High |
|---|---|---|
| No step on the way from the flat's entrance to the living room, the kitchen and one bedroom. Thresholds ≤ 12 mm, bevelled above 5 mm | Also one bathroom with a threshold ≤ 12 mm (a level shower) | Every room and balcony at ≤ 12 mm (≤ 20 mm, bevelled, at a balcony) |
Kind: standard (NBC Annex B; the Harmonised Guidelines).
The owner's answer. A bathroom stepped down scores the minimum; a level one, the medium. The rest of the flat is taken as level, as a flat's floors are but for its baths and balconies; the high level asks for the balconies' sills, which a drawing doesn't show.
SF-3 Stairs. Applies to stairs inside a house or duplex. A block's common stairs are building facts.
Gate fails when (NBC 2016 Part 3 §12.18; MBBL §4.17; or the city's rule):
the width is under 1.0 m (0.75 m in a two-storey row house);
the tread is under 250 mm;
the riser is over 190 mm;
a flight has more than 12 risers (UDCPR and UBBL allow 15);
headroom is under 2.2 m.
| Minimum | Medium | High |
|---|---|---|
| The code is met | Tread ≥ 300 mm, riser ≤ 150 mm, and a handrail | Also handrails on both sides at 850–950 mm, landings ≥ 1,200 mm, closed risers, no nosings that project, and no winders or spiral |
Kind: model code or city rule (gate); standard (NBC Annex B) for the higher levels.
On a drawing.
A stair is its flights and landings together: stair outlines within 300 mm of one another. A few steps (fewer than 8 risers drawn: a porch's, a sunk floor's) aren't a stair, nor is anything narrower than 600 mm (a ladder, or a sliver of a stair's reading).
The width and the going are measured. One within the drawing's precision of the code's value (13 mm across the stair, 6.5 mm in its treads' spacing, measured over all of them) is taken as meeting it.
The riser is the floor-to-floor height (printed, or the usual ceiling and 300 mm of floor) over the risers drawn. A plan cuts a stair on its way up and draws the rest on the floor above, so a riser steeper than the code allows is asked about (is the whole stair drawn, and what is the floor-to-floor height?), never failed. The flight's count of risers is the drawing's.
Headroom, handrails, landings' depth and nosings aren't on a drawing: the high level isn't given on the drawing alone.
SF-5 Falls. It needs the floor; a ground floor isn't scored. With the 900 mm sill assumed, windows from the 11th floor up become "check: a 1.1 m guard is expected", never a failure on the assumption alone.
Gate fails when balcony, terrace and verandah guards are under 1.0 m (NBC Part 3 §12.11; MBBL §4.12), or the city's height (Mumbai 1.5 m; Gujarat 1.15 m with gaps of 0.15 m at most). It is assumed met unless a lower height is printed.
| Minimum | Medium | High |
|---|---|---|
| A window's sill, or the barrier in front of it, at least 800 mm up to the 10th floor, 1,100 mm on floors 11–20, and 1,200 mm from the 21st | Also every window with a sill under 900 mm and a drop over 1.2 m is guarded (IS 4912); balcony guards ≥ 1,100 mm (1,200 mm from the 21st floor); no gap over 100 mm | Also glass with a sill under 750 mm and a drop over 1.5 m is laminated safety glass or has a rail; no guard with climbable rungs |
Kind: standard (NBC 2016 Part 6 Sec 8 Table 35; IS 4912 with Amendment 1).
On a drawing. A printed sill under the height its floor asks fails the minimum; an assumed one is asked about, and the check isn't scored until it is answered. The guards' heights aren't read from a drawing in edition 1.0: the gate is taken as met, and a home with a balcony is held at the minimum until its guards are known. The high level is a home with no sill under 900 mm and no balcony.
SF-6 Gas and the kitchen (gate and facts).
Gate fails when:
the kitchen has no opening to external air or an open verandah (also a cap, §8);
the kitchen is in a basement;
the hob stands under, or at the foot of, a stair (NBC 2016 Part 3 §12.3.3(d); Part 4 §4.7.9, §6.1.2(b)).
Facts:
whether the kitchen's exhaust can reach an outside wall directly;
where an LPG cylinder can stand in a ventilated spot at floor level (Part 9 Sec 4; IS 6044-1);
for piped gas, the meter's vent.
7Weights
7.1 Part weights. The defaults of Part 1 §7.3 apply.
7.2 Check weights within parts. Each check's weight is a share of its part. Where a check doesn't apply, it drops out and the rest share its weight.
| Part | Checks and weights |
|---|---|
| Space | SP-2 25 · SP-3 20 · SP-4 15 · SP-5 10 · SP-6 10 · SP-7 5 · SP-8 5 · SP-9 5 · SP-10 5 |
| Daylight | DL-2 70 · DL-3 30 |
| Sun | SN-1 w · SN-2 (1 − w), from 5.3 |
| Air | AR-1 10 · AR-2 25 · AR-3 20 · AR-4 10 · AR-5 15 · AR-6 20 |
| Layout | LY-1 15 · LY-2 30 · LY-3 20 · LY-4 10 · LY-5 25 |
| Safety & access | SF-1 35 · SF-2 20 · SF-3 20 · SF-5 25 (SF-6 is a gate) |
8Critical issues (caps)
Part 1 §7.4 applies to each of these:
A bedroom or living room with nothing to light it from outside, where the drawing shows windows elsewhere: no window, glazed door or open side to the outside, or to a balcony, a terrace or an open verandah.
A bedroom the way in reaches only through another bedroom (one the drawing's doors don't join to the way in at all is reached another way: a wing with a door of its own).
A kitchen with no opening of any kind (a window, a door, an open side) to external air or an open verandah, its service balcony among them, which is unsafe for gas and smoke.
9The size check
The size check is shown beside the score and never mixed into it.
9.1 Measured from the drawing.
The carpet area, as RERA §2(k) defines it: inside the external walls, with internal walls included, and shafts, exclusive balconies or verandahs and exclusive open terraces left out.
The balcony, verandah and terrace areas, separately, as RERA §4(2)(h) asks builders to disclose them.
IS 3861's "carpet area", which leaves out kitchens, baths and passages, is named as a different definition and never labelled carpet area.
9.2 Compared.
Printed sizes against the drawing: "19 of 20 printed sizes match", each with its receipt.
Printed areas against the measured ones: agreeing within 3%, close within 8%, or different.
The RERA-registered carpet area. The builder must register each unit type's carpet area, and it is public on the state RERA website (§4(2)(h), §11(1)). Where the owner enters it, the report compares the two.
"Builder says": carpet, built-up and super built-up area, entered from the brochure or the agreement. Loading is shown both ways, (super − carpet) ÷ carpet and carpet ÷ super, because the press uses both.
The price, where given, is shown per measured carpet sq ft.
9.3 The money at stake. Where the agreement's carpet area exceeds the measured one by more than 3% (areas within 3% agree, 9.2) and a price is given, the report shows the shortfall × the agreement's own rate, with its context:
the model agreement for sale (clause 1.7) refunds any reduction within 45 days, with interest, and lets the builder charge for an increase of up to 3%;
MahaRERA's model makes the clause non-negotiable;
the orders in the research file (MahaRERA 2026, the West Bengal tribunal, Telangana RERA) show it applied.
It is labelled: a plan-verified estimate, not a certified measurement; measure at handover, and compare with the agreement.
9.4 A difference of method is not a shortfall. A gap that comes only from the definition is said to be one: for example, an older agreement made under MOFA that counted balconies (MahaRERA, Deepak Pande v. L&T, 2021).
9.5 The verdict line:
"Sizes check out";
"A size needs a question";
"The printed sizes overstate the drawing".
10Facts and lenses shown, not scored
| Item | What it shows |
|---|---|
| The Vastu lens (off by default; per home and per link) | The plan's eight directional zones from its north. Which zone holds the entrance, the kitchen, the main bedroom, the pooja space, each toilet and the stairs, and whether the centre is open. Described, never scored; never "compliant". Without a north arrow or the owner's facing, there is no Vastu lens |
| The Eco-Niwas check | SN-2's estimate and the dwelling's openable ratio |
| IGBC's and IS 2440's daylight tests | DL-2 |
| Fan clearance | "At 2.4 m to a false ceiling, there is no legal room for a ceiling fan" (NBC Part 8 Sec 2) |
| Fixed window grilles | A fact, never a score |
| Noise by layout | LY-6 |
Annex A (normative): Corpus anchors
The rule. The anchors of SN-2 and AR-5 were fixed on the TIS-IN 1.0 reference set by Part 1 §6.4 on 7 October 2026, and are printed in their checks. SP-7's stay provisional: the set can't fix them (A.4). They are fixed again on a larger set during trial use, and change only with a new edition.
A.1 The reference set. The Indian plans of the Trueinch corpus, rebuilt at the current format: 119 plans, 76 of them real (brochures and listings, read by the product) and 43 generated (homes drawn by the corpus's generator in four drawing styles and rendered clean, at low resolution, photographed or as a phone picture, then read like any upload). A plan is a page of its drawing, as the product reads it: 16 of the 119 are a house's upper floor or a building beside it (a garage, a stable), and count for the rooms the checks judge in them. Each is placed at one of five cities in turn; a plan with a north arrow faces as it says (25), and the rest with the top of the drawing to each way in turn (94).
| City | Zone | Plans (real + generated) |
|---|---|---|
| Bengaluru | Temperate | 24 (16 + 8) |
| Mumbai | Warm-humid | 24 (15 + 9) |
| Delhi | Composite | 24 (15 + 9) |
| Chennai | Warm-humid | 24 (15 + 9) |
| Ahmedabad | Hot-dry | 23 (15 + 8) |
A.2 How it was measured. Every plan through the plan's own facts and the airflow network (SP-7 and AR-5); 42 of them through the sun's days as well (SN-2); and a sample of 12 (9 real, 3 generated), spread through the set so that it meets every city and every facing, through every engine but the 3D breeze, for the standard-anchored checks: the light model and the overcast daylight take most of a home's work. AR-6, which the 3D breeze measures, is left out of the yardstick. AR-5 is measured where a plan has a kitchen and a bedroom or living room (97 of the 119). The facts are kept, so the anchors can be fixed again without the engines (scripts/score/reference.py anchors).
A.3 The yardstick. On the sample, the standard-anchored checks leave 25% of the rooms and plans they judge short of their minimum, 39% short of their medium and 54% short of their high:
| Check | Judged | Short of the minimum | Of the medium | Of the high |
|---|---|---|---|---|
| SP-2 | 26 rooms | 0% | 4% | 4% |
| SP-3 | 11 rooms | 18% | 18% | 36% |
| DL-2 | 56 rooms | 20% | 30% | 45% |
| DL-3 | 56 rooms | 14% | 30% | 77% |
| SN-1 | 19 rooms | 0% | 5% | 5% |
| AR-1 | 56 rooms | 62% | 88% | 95% |
| AR-2 | 46 rooms | 6% | 22% | 33% |
| AR-3 | 10 plans | 70% | 90% | 100% |
| AR-4 | 23 rooms | 17% | 17% | 17% |
| LY-5 | 9 plans | 33% | 78% | 78% |
| SF-1 | 10 plans | 80% | 100% | 100% |
A.4 The anchors.
| Curve | Zero | Minimum | Medium | High | Short of the minimum: provisional → fixed | Judged |
|---|---|---|---|---|---|---|
| SN-2, kWh a day per m² of floor | 0.38 | 0.19 | 0.10 | 0.05 | 9% → 26% (scaled) | 197 rooms |
| AR-5, kitchen → bedrooms and living | 50% | 25% | 10% | 5% | 24% (kept) | 97 plans |
| AR-5, time for the living space to clear | 16 min | 8 min | 4 min | 2 min | 1% → 21% (scaled) | 97 plans |
| AR-5, WC → kitchen and dining | 25% | 10% | 5% | 2% | 32% (kept) | 97 plans |
| SP-7, floor only for passing | 30% | 15% | 10% | 7% | 6% (provisional) | 117 plans |
SN-2 was 0.60, 0.30, 0.15 and 0.08: a quarter of the set's rooms take more of the hot days' sun through their glass than its minimum, as the bare east or west room of 6.3 does, and one with a 600 mm chajja just does.
AR-5's clearing was 120, 60, 30 and 15 minutes: with the windows open in the usual wind, the set's living spaces clear in minutes (half within 4, nine in ten within 12), and 27 of the 97 never get a tenth of the kitchen's strongest at all.
SP-7 stays provisional. 80 of the 117 plans (68%) have no floor only for passing as their drawings name it: a flat's passage is mostly part of its living floor, which the measure leaves out. Matching the yardstick would put the minimum at 4% of the floor, and make any passage at all the fault rather than how much of the floor it takes. SP-7 needs a measure of circulation the set can fix: the floor the walks between the doors take, which furniture can't.
Annex B (normative): Climate and city rules
B.1 Climate zones of cities. From Eco-Niwas Samhita's city table, as reproduced by IGBC.
| Zone | Cities |
|---|---|
| Warm-humid | Mumbai, Chennai, Kolkata, Pune, Kochi, Visakhapatnam, Guwahati, Goa (Panaji), Thiruvananthapuram, Bhubaneswar, Mangaluru, Belgaum, Jamnagar, Ratnagiri, Tiruchirappalli and others |
| Composite | Delhi (and NCR, by adjacency), Hyderabad, Jaipur, Lucknow, Chandigarh, Bhopal, Indore, Nagpur, Dehradun, Patna, Allahabad, Amritsar, Ludhiana, Raipur, Ranchi and others |
| Hot-dry | Ahmedabad, Surat, Vadodara, Jodhpur, Bikaner, Jaisalmer, Kota, Aurangabad, Sholapur and others |
| Temperate | Bengaluru |
| Cold | Shimla, Srinagar, Leh, Manali, Kullu, Shillong, Udhagamandalam and others |
Notes.
Pune is warm-humid, and Jaipur, Hyderabad and Nagpur composite, in this table. Other sources disagree, and the report shows the zone the typical year gives as well.
Cities not listed, such as Coimbatore, are worked out from the typical year by NBC Part 8 Table 2.
B.2 Regional wind patterns. These only flag a typical year that looks wrong; they are not inputs.
| Region | Pattern |
|---|---|
| West coast (Mumbai, Goa, Kochi) | Strong W/SW in the monsoon; W/NW sea breezes in the afternoon the rest of the year |
| East coast (Chennai, Visakhapatnam, Bhubaneswar, Kolkata) | S/SE sea breezes on summer afternoons; W/SW in the monsoon; NE from October to December |
| Gangetic plain and north-west (Delhi, Lucknow, Jaipur, Chandigarh) | Hot W/NW before the monsoon; E/SE in the monsoon; calm winters |
| Deccan and centre (Bengaluru, Hyderabad, Pune, Nagpur) | Steady W/SW in the monsoon; E/NE in winter |
B.3 City rules that replace NBC's numbers. These are read in the rules' own texts. Their later amendments are to be checked before 1.0 leaves trial use.
| Item | NBC 2016 | Maharashtra (UDCPR 2020) | Mumbai (DCPR 2034) | Delhi (UBBL 2016) | Haryana (2017) | Gujarat (CGDCR 2017) |
|---|---|---|---|---|---|---|
| First habitable room | 9.5 m², 2.4 m | None | No area; every room 2.4 m wide | Flats ≤ 50 m²: 7.5 m², 2.1 m; larger: 9.5 m², 2.4 m | As NBC | One room of 9.0 m², 2.4 m |
| Other rooms | 7.5 m², 2.1 m | None | 2.4 m wide | 7.5 m² | 7.5 m², 2.4 m (group housing) | — |
| Kitchen | 5.0 m², 1.8 m | None | 1.8 m wide | 3.3 m², 1.8 m / 4.5 m², 2.4 m | 5.5 m², 1.8 m | — |
| Bath / WC / combined | 1.8 / 1.1 / 2.8 m² | 1.0 × 1.2 m / 0.9 × 0.9 m / 1.5 m² | 1.5 / 1.1 / 2.2 m² | 1.2–1.8 / 1.0–1.2 / 1.8–2.8 m² | As NBC | WC 0.9 m² |
| Openings | 1/10–1/6 by climate; kitchen +25% | 1/10; kitchen ≥ 1 m² | 1/6; ≥ 1 m² a room | 1/10; kitchen ≥ max(1 m², 1/10) | 1/8 | 1/10, and 1/7 including doors |
| Bath / WC window | 0.3 m² | 0.3 m² | 0.3 m² | 0.37 m² | 0.3 m² | 0.25 m² to a 0.9 × 0.9 m open space |
| WC not into the kitchen | Yes | — | — (no WC above a kitchen) | — | Yes | — |
| Bath / WC height | 2.1 m | 2.1 m | 2.2 m | 2.2 m | 2.45 m | 2.1 m |
| Parapet or guard | 1.0–1.2 m | 1.0–1.2 m | ≥ 1.5 m (as printed) | 1.0–1.5 m; 1.8 m at ≥ 24 m | Maximum only | ≥ 1.15 m, gaps ≤ 0.15 m |
| Stair in a dwelling | 1.0 m; 250 / 190 mm; ≤ 12 risers | 0.75 m; 25 / 19 cm; ≤ 15 | 0.9 m; ≤ 12 | 0.9–1.0 m; 25 / 19 cm; ≤ 15 | 0.9 m; 25 / 19 cm; ≤ 14 | 1.0 m; 250 / 200 mm |
| Doors | — | 0.90 m; bath/WC 0.75 m | 0.9 m; 0.7 m | 0.90 m; 0.75 m | 0.90 m; 0.75 m | — |
Karnataka, Tamil Nadu (CDCBR 2019), Telangana and Kerala (KMBR 2019) are in the research notes. They are added here when confirmed.
Annex C (normative): Room hours and the design household
Hours a day, from India's Time Use Surveys (MoSPI). Bedrooms are per occupant; the kitchen and study are totals for the household.
| Room | All hours (Air, Space) | Daylight hours, 06:00–18:00 (Daylight, Sun) |
|---|---|---|
| Bedroom, per occupant | 9.5 (8.3 sleeping, 1.2 awake) | 1.0 (2.0 for an elder or a child) |
| Living (hall) | 4.0 | 3.0 |
| Dining | 1.5 | 0.7 |
| Kitchen (household total) | 2.5 | 2.0 |
| Study (household total) | 1.5 | 1.5 |
| Bath and WC | 1.0 | Not scored |
| Utility or balcony | 0.5 | 0.5 |
| Pooja room or unit | 0.3 (smoke from lamps and incense) | Not scored |
Room weight = its hours × the people who use it:
a bedroom: its occupants;
the living and dining rooms: the design household;
the kitchen and study: their totals as given.
What this means for a 2BHK of four.
| Part | Bedrooms | Living | Dining | Kitchen | Baths | Study | Utility |
|---|---|---|---|---|---|---|---|
| Air | 57% | 24% | 9% | 4% | 6% | — | 1% |
| Daylight | 24% | 48% | 11% | 8% | — | 6% | 2% |
The kitchen's needs are carried by its own higher lux levels and by SP-4 and LY-5.
Basis and households.
The hours come from the Time Use Survey 2019 and 2024: sleep about 8.3 h; leisure at home about 2.7 h; domestic work about 3.9 h for women.
Urban households average 4.8 people (Census 2011), and 16% of urban households hold two or more married couples.
In a 3BHK or larger, one bedroom is assumed to be an elder's (2 waking hours).
A home of more than four bedrooms is assessed for its bedrooms + 2 people (a 5BHK 7, a 6BHK 8): the rule the households of §3 follow from 2BHK on, each bedroom beyond adding one person.
Annex D (normative): Furniture and clearances (Indian sizes)
| Piece | Size |
|---|---|
| Mattress (W × L) | Single 36 × 75″ · double 48 × 75″ · queen 60 × 75″ · king 72 × 75″. Lengths of 72 or 78″ where shown |
| Wardrobe | 600 mm deep, with 600 mm clear in front |
| Kitchen platform | 600 mm deep, at 850–900 mm high. Wall units 300–350 mm deep. Chimney 650–750 mm above the hob |
| Fridge | Single-door 550 × 650 mm; double-door 650 × 700 × 1,700 mm |
| Front-loading washing machine | 600 × 600 × 850 mm |
| Sofa | Three-seat 2.1 × 0.9 × 0.85 m |
| TV | 55″ |
| Dining table | Four seats 1,200 × 750–900 mm; six seats 1,500–1,800 × 900 mm |
| Shoe cabinet | 900–1,200 × 300–350 mm |
| Pooja unit | 600–900 × 300–450 mm, or a room of about 1.2 × 1.2 m |
| Servant's room | About 2.4 × 2.4 m, with its own WC |
Clearances:
| Where | Clearance |
|---|---|
| Bed | 600 mm (minimum), 750 mm (high) |
| Dining chairs | 750 / 900 / 1,000 mm |
| Kitchen aisle | 900 / 1,000 / 1,200 mm |
| In front of a WC or basin | 600 mm (NBC) |
Annex E (normative): Conformance plans
The conformance plans are reference plans with their expected scores and tolerances (Part 1 §11). They are published with the reference set.
Annex F (informative): Sources, and what to confirm
The research notes behind each number:
G: Indian codes, measurement, accessibility and safety;
H: Indian households, climate, green and comfort standards;
K: method;
the research.
To confirm before 1.0 leaves trial use:
every NBC value against the 2026 text;
the city rules' later amendments, and the southern states' values;
IMAC-R's equation for homes. Until then, IMAC's 80% band stands in;
NBC Part 8 Table 9's partly illegible row;
the London Plan's balcony size;
Indian mattress sizes, for which there is no BIS standard;
MahaRERA's model clause and its order number;
SP-7's anchors, on a measure of circulation the reference set can fix (Annex A);
w by city, computed on the typical years.
Annex G (informative): Where the texts disagree, and what this Part does
| Topic | The disagreement | What TIS-IN does |
|---|---|---|
| Openings | NBC counts only openable area; the plan once had two code checks for it | One gate (DL-1); AR-1 graded only |
| Glazed doors | NBC 2016 §20.1.2 counts windows and ventilators, "excluding doors"; MBBL 2016 §4.30 names glazed doors among a room's apertures for light and air | A glazed door counts by what opens of it; a plain door doesn't |
| The utility | A flat's utility is its service balcony, open to the air; a house's utility room is a room | Open to the air, as a balcony is, unless it is named a room |
| Carpet area | NBC defers to IS 3861, which leaves out kitchens and baths; RERA §2(k) includes them | RERA's carpet area only; IS 3861 named as different |
| Third and later rooms | NBC 12.2.2 words one or two rooms | "The largest 9.5 m², the rest 7.5 m²", as the city rules write it |
| Air changes | NBC: bedroom 2–4, no kitchen row; IS 3362: bedroom and living 3, wet rooms 6 | NBC's bands for the still-air test; IS 3362 for wet rooms |
| Cross-ventilation | IGBC counts any two orientations from 25%; Eco-Niwas Samhita counts adjacent or opposite walls from 50%, with doors shut | Eco-Niwas Samhita's levels; IGBC's rule for doorless openings; an airflow check besides |
| Guards | NBC Part 3: 1.0–1.2 m; Part 6 Table 35: 1.1 m, 1.2 m higher up; Mumbai: 1.5 m | The gate at NBC Part 3 or the city's rule; Table 35 at medium |
| Stair risers per flight | NBC 12; UDCPR and UBBL 15; Haryana 14 | NBC, or the city's rule |
| Climate zones | Eco-Niwas Samhita's city table against NBC's rule applied to weather | The table for listed cities; both shown when they differ |
| Daylight skies | IS 2440 and NBC use a clear design sky (90% of hours); EN 17037 an overcast median (50% of hours) | Scored by the EN 17037 method; IS 2440's test shown |
| Glazing | NBC wants more opening in warm-humid zones (1/6); Eco-Niwas Samhita's RETV pushes heat-gaining glass down | Resolved by climate: Sun's mix, and SN-2's per-room heat |
| Chajjas | They cut solar gain, but slow the breeze indoors | The sun modelled; the breeze from edition 1.1 |